Dimms; Hpe Smart Storage Battery - HP ProLiant WS460c Gen9 Maintenance And Service Manual

Graphics server blade
Table of Contents

Advertisement

To replace the component, reverse the removal procedure.

DIMMs

CAUTION: To prevent improper cooling and thermal damage, always install DIMMs of the
same height on the graphics server blade. This graphics server blade does not support
mixing standard and non-standard height DIMMs.
To identify the DIMMs installed in the graphics server blade, see "DIMM identification (on page 93)."
To remove the component:
Power down the graphics server blade (on page 25).
1.
Remove the graphics server blade
2.
Place the graphics server blade on a flat, level work surface.
3.
Remove the access panel
4.
Remove the mezzanine assembly
5.
Remove the FlexibleLOM ("FlexibleLOM" on page 49).
6.
Remove the storage controller
7.
Disconnect the direct connect SATA cable, if installed
8.
Remove the internal USB drive, if installed. To locate the internal USB connector, see "System
9.
board components (on page 91)."
Remove all DIMM baffles
10.
Remove the DIMM.
11.
To replace the component, reverse the removal procedure. To configure the memory mode, use UEFI
System Utilities

HPE Smart Storage Battery

To remove the component:
Power down the graphics server blade (on page 25).
1.
Remove the graphics server blade
2.
Remove the access panel
3.
Place the graphics server blade on a flat, level work surface.
4.
("Access panel (graphics server
("Storage
("DIMM
baffles" on page 51).
("HPE UEFI System
Utilities" on page 75).
("Access panel (graphics server
("Remove the graphics
("Mezzanine
assembly" on page 34).
controller" on page 50).
("Direct connect SATA
("Remove the graphics
blade" on page 26).
blade)" on page 31).
cabling" on page 80).
blade" on page 26).
blade)" on page 31).
Removal and replacement procedures 53