Sensor Failure: #A3-3310. Turn Off Then On. Call For Service If The Problem Persists; Sensor Failure: #A3-3311. Turn Off Then On. Call For Service If The Problem Persists; Sensor Failure: #A3-3312. Turn Off Then On. Call For Service If The Problem Persists; Sensor Failure: #A3-3410. Turn Off Then On. Call For Service If The Problem Persists - Samsung SL-X7600GX Service Manual

A3 color copier
Table of Contents

Advertisement

4. Troubleshooting
► Error Code
A3–3310
A3–3311
A3–3312
A3–3410
A3–3411
A3–3412
► Error message

Sensor Failure: #A3-3310. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3311. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3410. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3411. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3412. Turn off then on. Call for service if the problem persists

► Symptom
Outer temperature/humidity sensor is defective.
► Troubleshooting method
A3–3310 / A3–3311 / A3–3312 : Temperature function is abnormal.
A3–3410 / A3–3411 / A3–3412 : Humidity function is abnormal.
1) Turn the machine off then on.
2) Check the connection between the outer temp sensor and main board. If the connection is OK, replace the outer
temp sensor .
3) If the sensor is normal, replace the main board.
4-95
Copyright© 1995-2013 SAMSUNG. All rights reserved.

Advertisement