Sensor Failure: #A3-3210. Turn Off Then On. Call For Service If The Problem Persists; Sensor Failure: #A3-3211. Turn Off Then On. Call For Service If The Problem Persists; Sensor Failure: #A3-3212. Turn Off Then On. Call For Service If The Problem Persists - Samsung SL-X7600GX Service Manual

A3 color copier
Table of Contents

Advertisement

► Error Code
A3–3210
A3–3211
A3–3212
► Error message

Sensor Failure: #A3-3210. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3211. Turn off then on. Call for service if the problem persists

Sensor Failure: #A3-3212. Turn off then on. Call for service if the problem persists

► Symptom
Inner temperature sensor is defective.
► Troubleshooting method
A3–3210 : Inner temperature sensor value is abnormal.
A3–3211 : Inner temperature sensor is in short status.
A3–3212 : Inner temperature sensor is in open status.
1) Turn the machine off then on.
2) Check the connection between the inner temp sensor and main board. If the connection is OK, replace the inner
temp sensor .
3) If the sensor is normal, replace the main board.