Samsung SL-X7600GX Service Manual page 307

A3 color copier
Table of Contents

Advertisement

Diagnostics > Adjustment > Scan Area Adjustment > Manual Adjustment
Purpose
Operation Procedure
Copyright© 1995-2013 SAMSUNG. All rights reserved.
To correct image position and magnification of scanned images manually.
1) Choose one item from the table. There are three items to choose.
Image Position - Leading Edge (Unit : mm, Scale : 0.1, Min/Max : -6/+6)
Image Position - Side Edge (Unit : mm, Scale : 0.1, Min/Max : -6/+6)
Magnification - Vertical Direction (Unit : %, Min/Max: 98.5/101.5)
2) Select one item and press the "Edit" button.
3) Change the adjustment value with arrow button.
4) Image Position (a, b) : If the current value is smaller than the specification, press "+".
Otherwise, press "-".
5) Magnification (c) : If the current value is smaller than the specification, press "-". Otherwise,
press "+".
6) Press the "OK" button to apply the new value to the system.
7) Scan the Scanner A/S Chart and send it to a PC. Scanning must be occur from the scan glass.
8) To check the image position, compare the position of scale marks (a,b) of the chart to the
scanned image.
9) To check the magnification, compare the length of line "c" of the chart to the scanned image.
NOTE
Specification
a,b : 10, ± 1.5 mm
c: 190, ± 1.5 mm
4. Troubleshooting
4-56

Advertisement

Table of Contents
loading

Table of Contents