Point Of View Of The Inputs And Outputs To The Electric Module - Etesia HYDRO 124D Technical Training Manual

Table of Contents

Advertisement

From the point of view of the inputs and outputs to the electric module :
If
= Input
Then
= Output
Closed
= current passes
Open
= no current passes
Live
= +12V
Stop
= 0V
Initial stage :
Opening
Input : switch opening mobile basket = closed
1) Output : flap closing coil = live
2) Input :
horizontal flap contactor = open
3) Output : revolving warning light = live / flap closing coil = live
basket opening coil = live / (blade clutch = stop*)
Input : mobile basket opening switch = open
Closing
Input : mobile basket closing switch = closed
1) Output : flap closing coil = live
2) Input :
vertical flap contactor = closed
3) Output : flap closing coil = live / basket closing coil = live
4) Input :
mobile basket contactor = closed (and fixed basket contactor = closed)
5) Output : (blade clutch = live*) / flap opening coil = live
6) Input :
horizontal flap contactor= closed
7) Output : revolving warning light = stop.
Input : mobile basket closing switch = open
(*If the blades were in operation when emptying was begun.)
- 64 -
Input : horizontal flap contactor = closed
Input :
mobile basket contactor = closed
Input :
fixed basket contactor = closed

Hide quick links: