Connecting the power terminal
f Connect the cables to the terminal board with solderless ring terminals.
f
f Only sue the certified and rated cables and make sure to firmly connect them without applying any external force to the
f
terminal.
f Connect with a driver and a wrench that are able to apply the rated torque to the screws.
f
f Connect the terminal screws according to the rated tightening torque. If the terminal is loose, fire can occur due to arc
f
heat generation and if the terminal is too tight, terminal board could get damaged.
Screw
M3
M3 . 5
M4
M5
M6
Connecting the wires
f Product uses single phase, 220V power supply.
f
f When connecting indoor and outdoor unit connection cable, make sure to match the numbers (or letters) on outdoor
f
unit side to indoor unit side. Make sure to connect the indoor and outdoor unit communication cable to the connector
within the electrical component box of each unit. (incorrect connection of the indoor and outdoor unit connection cables
may cause malfunction of the product.)
f When you connect connection and power cable of the indoor and outdoor unit, make sure that they don't touch
f
the service valve on the refrigerant pipe (gas side) or the pipes without the insulator. Fix the indoor and outdoor unit
connection cable to the insulated pipes.
f If the wiring standard is not complied, there is a risk of a fire.
f
f When you install the circuit breaker, make sure to fix it firmly within the electrical component box.
f
Mirage_AP36M0@_IBIM_E_34573A(1).indd 43
Tightening torque (kgf∙cm)
5.0~6.0
8.0~10.0
12.0~15.0
20.0~25.0
25.0~30.0
43