Samsung APC4082E Installation Manual
Samsung APC4082E Installation Manual

Samsung APC4082E Installation Manual

Indoor unit/outdoor unit
Hide thumbs Also See for APC4082E:

Advertisement

Quick Links

Grieta de Colmado de Aire Acondicionado
Climatiseur Monobloc de Type Split
E S F A DB98-04436A(1)
INSTALLATION MANUAL
MANUAL DE INSTALACIÓN
MANUEL D'INSTALLATION
Indoor Unit
APC4082E
APC4082EC
Split-type Packged Air Conditioner
Outdoor Unit
UPC4082E
UPC4082EC
(Cool)
(Refrigeración)
(Refroidissement)

Advertisement

Table of Contents
loading

Summary of Contents for Samsung APC4082E

  • Page 1 INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D’INSTALLATION Indoor Unit Outdoor Unit APC4082E UPC4082E APC4082EC UPC4082EC Split-type Packged Air Conditioner (Cool) Grieta de Colmado de Aire Acondicionado (Refrigeración) Climatiseur Monobloc de Type Split (Refroidissement) E S F A DB98-04436A(1)
  • Page 2: Table Of Contents

    Be sure to read the installation manual carefully to ensure sufficient realization of the excellent performance of the unit. Be sure to drill a hole in the wall necessary for installation before attempting to install the unit. After completion of installation, be sure to perform a test operation of the unit to check for any problem, and then deliver the unit to the customer if the test results are acceptable.
  • Page 3: Connection Parts

    ACCESSORY PARTS LIST Connection Parts Others Part Name Q’ty Remarks Part Name Q’ty Remarks Drain hose Putty Connection pipe Insulation for drain hose " (ø9.52mm) Connection pipe Cable-tie Piping Box " (ø19.05mm) Insulation for piping Insulation tape Piping Box Finishing tape Connecting wire (4 strand) Leg holder for Digital telecommunicator...
  • Page 4: Selection Of Installation Place

    SELECTION OF INSTALLATION PLACE Indoor Unit Install the unit at a place close to the wall facing the outside as Top view it is necessary to perform piping connection with the outdoor unit. - It is effective to install the unit at a window side to ensure uniform distribution of indoor temperature.
  • Page 5: Electrical Work

    Be sure to install circuit breaker (separately purchased by the user). Be sure to connect the grounding wire. Electric power spec ITEM SPEC APC4082E/APC4082EC Model Single phase 220-240V, 50Hz Power Sub switch Electric wire 4.0mm...
  • Page 6 ELECTRICAL WORK Indoor and Outdoor Connection Wiring 1. When connecting the wiring harness between the indoor and outdoor unit, align the outdoor side with the terminal board No., and fix it securely by using the anchorage. 2. Connect the indoor side wire. 1) Disassemble the cover control by unfastening two screws.
  • Page 7 Wiring diagram Control box Earth Indoor unit terminal block Earth Earth Power Cable Indoor and outdoor Power cable connection wire Indoor unit Outdoor unit...
  • Page 8: Installation Method

    INSTALLATION METHOD Outdoor Unit When using the anchor bolt Anchor bolt fixing dimensions 1. Fix the unit on a flat, rigid floor using the anchor bolt. 840mm (Anchor bolt : M10 x 4 points - separately purchased) 415mm When using the leg holder of the outdoor unit 1.
  • Page 9: Installation Procedures

    Installation Procedures 1. Open the front panel, and remove the flare nut. 2. Bend the connection pipe to an appropriate length using the spring bender depending upon the installation place. - Allowable pipe length : Maximum 20m - Allowable pipe drop distance : Maximum 15m - Make no more than ten bending points on the pipe When the pipe length is in excess of the standard pipe length of 5m, add the refrigerant (R22) of 70g for each additional 1m.
  • Page 10: Connection Of Refrigerant Piping

    INSTALLATION METHOD Connection of Refrigerant Piping Flare Processing 1. Cut the pipe using the pipe cutter. Oblique Roughness Burr 2. Insert the flare nut into the pipe, and then perform the flare processing. Outer Diameter A(mm) ø 9.52mm ø 19.05mm...
  • Page 11 Pipe Bending 1. Perform bending of the pipe using the bender which has a specified bending radius. Spring 2. Be sure to take full care to perform bending of the pipe successfully at one time. Bending and unbending the pipe more than twice makes the bending work increasingly difficult.
  • Page 12: Drilling A Hole In The Wall

    INSTALLATION METHOD Drilling a Hole in the Wall Drill a hole of 60mm in diameter to the outside. The drilling should be done at a distance of less than 200mm from the floor facing the indoor unit. Ø 60mm Less than 200mm Drain Hose Extend the drain hose to the drain hose connected to...
  • Page 13: Connecting The Pipe

    Connecting the Pipe The piping of this unit can be connected to the right, left, and rear side. When you hit the area for piping connection slightly with a hammer, a hole is made. After connecting the piping and drain hose, insert the rubber cap as shown in the figure. Holes for piping connection (3 points) The shape of hole may varies with the models.
  • Page 14: Air Purge

    AIR PURGE Be sure that all valve cocks are closed. The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling capacity and could lead to a malfunction. Use Vacuum Pump as shown at the figure.
  • Page 15: Refrigerant Charging

    REFRIGERANT CHARGING Air purge(at the time of new installation only) Close the gas pipe side valve by turning it clockwise. Connect the pressure gauge to the low pressure side service valve, and then open the gas pipe side valve again. Connect it to the refrigerant filling tank.
  • Page 16: Check And Test Operation

    CHECK AND TEST OPERATION Check Be sure to check the following again after completion of installation. 1. Check the piping connection area for any gas leakage. Indoor Outdoor connection area connection area 2. Is the drain hose properly connected? 3. Is the insulation of the piping in good condition? 4.
  • Page 17 Test Operation After checking, read the owner’s instructions carefully, and perform a test operation. Then deliver the unit to the customer. (When delivering the unit, be sure to read carefully and follow the contents of the owner’s instructions.) CAUTION 1. Be sure to check whether the service valve is opened before attempting to perform the test operation.
  • Page 18: Installation Of Digital Telecommunicator

    INSTALLATION OF DIGITAL TELECOMMUNICATOR Select installation place Connect telephone cable Connect power cable Check the password Check and test operation Selection of Installation Place Decide the installation place referring to the figure below. about 10m Indoor unit...
  • Page 19 Avoid following conditions when installing the digital telecommunicator. (There must be no obstacles between the indoor unit and the digital telecommunicator.) Select the place above 30cm or more from the floor. 30cm It is recommended that the digital telecommunicator faces the front of the indoor unit.
  • Page 20 INSTALLATION OF DIGITAL TELECOMMUNICATOR Connection of Phone Cable and Power Cable Connect the phone cable. - Never invert the LINE-LINE cable and the LINE-PHONE cable. Otherwise, the digital telecommunicator will not be operated. The digital telecommunicator does not work if it is connected with the key phones normally used in the office. Connect DC adaptor to the digital telecommunicator.
  • Page 21 Checking Password Check if the digital telecommunicator beeps once by pressing the RESET button on the back of the telecommunicator. - If the digital telecommunicator does not beep, turn the air conditioner off and press buttons at the same time on the indoor unit until the unit beeps. After the indoor unit beeps, press the On/Off button on the indoor unit once within 3 seconds.
  • Page 22 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ELECTRONICS Printed in Korea...

This manual is also suitable for:

Apc4082ecUpc4082eUpc4082ec

Table of Contents