MAINTENANCE

2.1 ANNUAL MAINTENANCE
Maintenance consists of the following:
• Remove fi rst the embers and logs set from the main burner and carefully clean
these with a soft brush.
• Clean and inspect (visually) the main burner, pilot light, combustion chamber,
fl ue system and combustion air intake. Dust can be removed using a vacuum
cleaner.
• Clean the glass on the inside of the appliance with glass spray or ceramic hob
cleaner.
• After cleaning;
Carefully replace the embers and logs set on and around the main burner according
to the installation directions in this instruction booklet.
Do not place any embers or logs against the pilot light burner. Make sure that
the pilot fl ame can burn at all times freely over the main burner. Only in this
way is proper ignition of the main burner ensured.
Ignoring these directions could lead to a dangerous situation.
• Check the gas supply, fl ue system, and combustion air supply route for leaks.
• Check the correct operation of the gas regulating block, thermocouple
circuit and the ignition of the main burner.
• Check the gas inlet-pressure (both when the appliance is off and when it burns
at maximum) and the burner pressure.
• Check the complete concentric fl ue system including the outlet construction.
A camera can be used to inspect the whole length of the fl ue gas outlet and the
combustion air intake.
Also check that all connections are secure.
50
It is essential that the appliance, the complete concentric
fl ue system (where possible) and the outlet are cleaned and
inspected annually by a recognised fi tter/gas specialist.
The safe operation of the appliance will thus remain
guaranteed.