Bellfires VENTO CLASSIC SMALL Installation Instructions & Manual For Maintenance page 34

Table of Contents

Advertisement

Bellfi res
1.6.3 Gas connection
Operation (gas regulating block (and receiver)) outside the appliance (in the operating
unit):
The gas connection is situated where the operating unit is built in near to the appliance.
Use only gas piping with a minimum diameter of 1/2" and a shut-off valve.
1.6.4 Operating unit
If the appliance is fi tted with an operating unit comprising gas control block and receiver,
this will be located, once it has been built in, at a maximum of 50 cm from the left or
right hand side of the appliance.
1.7
POSITIONING THE APPLIANCE
Important:
The fi replace is constructed on a suffi ciently solid fl oor that
can bear the weight of the appliance.
Ensure a free space of at least 1 cm between the bottom of
the appliance and the fl oor.
Ensure that the temperature of the fl oor under and in front of
the appliance can never rise above 85°C!
Make use of a temperature protection plate (of nonfl ammable
material) on the fl oor if necessary.
Take care with a fl oor made of a fl ammable material.
Never position the appliance directly against the rear wall,
but always place an nonfl ammable insulation plate, at least
12 mm thick, between the appliance and the rear wall, with
free space on either side of 2 cm. (Total ± 5 cm.)
The rear wall must be made of nonfl ammable material.
Never use combustible materials during the installation.
Ventilate the fi replace, by allowing vents above and
below the fi replace.
During installation of the gas fi re, a clearance of 3 mm
should be maintained on all sides of the appliance to
allow for expansion of the appliance during operation.
34
English
Installation instructions