Installation manual
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
shall be installed for the protection of children and other
at-risk individuals.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death or property damage.
- Do not store or use gasoline or other fl ammable vapors and liquids in
the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer,
service agency or the gas supplier.
This appliance may be installed in an aftermarket, permanently located home
or mobile home, where not prohibited by local codes. This appliance is only
for use with the types of gas indicated on the rating plate. A conversion kit is
supplied with the appliance.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
INSTALLER:
Leave this manual with
the appliance.
CONSUMER:
Retain this manual for
future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BEL VBMT-3NG-SB and is the answer not in the manual?

Questions and answers

Summary of Contents for Bellfires BEL VBMT-3NG-SB

  • Page 1 Vertical Bell Medium Tunnel 3 LF Direct Vent Gas Fireplace Installation manual HOT GLASS WILL INSTALLER: CAUSE BURNS. Leave this manual with DO NOT TOUCH GLASS the appliance. UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. CONSUMER: A barrier designed to reduce the risk of burns from the Retain this manual for hot viewing glass is provided with this appliance and shall be installed for the protection of children and other...
  • Page 3: Table Of Contents

    CONTENTS Page IMPORTANT SAFETY INSTRUCTIONS ............CODE APPROVAL ................... PRE INSTALLATION INSTRUCTIONS ............GENERAL ....................CONCENTRIC FLUE SYSTEMS ............. INCLUDED WITH THE APPLIANCE ............OPTIONS AND ACCESSORIES .............. CLEARANCES ....................VENT INSTALLATION ..................POSITIONING THE APPLIANCE ..............GAS LINE INSTALLATION ................BUILDING IN THE APPLIANCE ...............
  • Page 4 Bellfi res Installation instructions...
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING: Improper installation, adjustment, alteration, services or maintenance can cause serious injury or property damage. Refer to this manual. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Bellfi res direct vent gas fi replace appliance. INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Keep the area around your appliance clear of combustible materials, gasoline and other fl ammable vapor and liquids. Do not place embers, vermiculite granules or wood logs against the pilot light burner. Make sure that the pilot flame can burn at all times freely over the main burner.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS 20. Keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust. Turn off the gas valve and appliance (OFF on remote control) before cleaning the appliance. 21.
  • Page 8: Code Approval

    IMPORTANT SAFETY INSTRUCTIONS CODE APPROVAL Direct Vent type appliances draw all combustion air from outside of the dwelling through the vent pipe. These appliances have been tested by CSA and found to comply with the established standards for VENTED GAS FIREPLACES in Canada as follows: LISTED VENTED GAS FIREPLACES Vertical Bell Medium Tunnel 3 LF tested to: - ANSI Z21.88-2014 / CSA 2.33-2014 Vented Gas Fired Heaters.
  • Page 9: Pre Installation Instructions

    PRE INSTALLATION INSTRUCTIONS WARNING: Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies. IMPORTANT : This appliance is solely intended for installation and use in Canada. GENERAL This ‘direct vent’ gas appliance must be installed by a qualifi ed installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA- B149.1 or .2 Installation Code This appliance, when installed, must be electrically connected and grounded in accor-...
  • Page 10: Concentric Flue Systems

    PRE INSTALLATION INSTRUCTIONS The appliance can be installed as an insert into an existing open fi re place or as a built- in appliance in a new fi re place. In order to prevent the fi replace heating up excessively, it must be properly ventilated by installing vents at the top of the fi...
  • Page 11: Options And Accessories

    PRE INSTALLATION INSTRUCTIONS OPTIONS AND ACCESSORIES The following options and accessories can be supplied by your dealer: Part no Accessory 329874 Set carrying brackets (2 pieces) 330361 Set of high adjustable feet (4 pieces) Feet height: max. +13¾ in. 321055 Mantel iron L = 780 mm 337801 High altitude kit 2 000 - 4 500 ft...
  • Page 12: Clearances

    CLEARANCES WARNING: Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fi re hazard. UNIT MUST SIT ON NON COMBUSTABLE SURFACE The appliance must be installed on a non-combustible fl oor. If installed on, for example, carpet or vinyl fl...
  • Page 13 CLEARANCES Clearances to combustible material Minimum clearances to combustible sides: Always place a non-combustible insulation plate/board(*) (false side wall) between the appliance and the side wall according to figure 1. The minimum thickness of the non-combustible insulation plate/board(*) and the minimum clearances to combustible material as shown in fi...
  • Page 14 CLEARANCES Clearances to combustible material Minimum clearances to combustible ceiling (and non-combustible ceiling): Place a non-combustible insulation plate/board(*) (false ceiling) with a thickness of min. 1" (2.5 cm) at a height of minimum 20" (50 cm) above the appliance. Maintain a free space of minimum 4"...
  • Page 15 CLEARANCES Clearances to non-combustible material Minimum clearances to non-combustible sides: Always place a non-combustible insulation plate/board(*) (false side wall) between the appliance and the side wall according to figure 3. The minimum thickness of the non-combustible insulation plate/board(*) and the minimum clearances to non-combustible material as shown in fi...
  • Page 16 CLEARANCES Clearances to non-combustible material Minimum clearances to non-combustible ceiling: Place a non-combustible insulation plate/board(*) (false ceiling) with a thickness of min. 1" (2.5 cm) at a height of minimum 20" (50 cm) above the appliance. Alternative: Without a false ceiling: Create an open space of minimum 8" (20 cm) height (h) between the non-combustible ceiling and the chimney enclosure.
  • Page 17 CLEARANCES Ventilation Ventilate the fi replace/chimney breast: • all spaces between the appliance and the insulation plates • all spaces between the insulation plates an all surrounding walls by allowing vents above. With false ceiling: Minimal required net vent openings above must be total 46 sq ins (300 cm This can be done by ventilation openings or grills.
  • Page 18 CLEARANCES Mantel clearances Any mantel piece made of combustible material should be placed at least 2" from the side and top of the fireplace opening. Minimum mantel clearances are shown in figure 5 to 7. False ceiling panel Non-combustible insulation plate/board 1"...
  • Page 19 CLEARANCES Depth of mantel [inch] Non-combustible material Insulation plate / board Combustible Combustible mantel piece mantel piece Top of fi replace opening Side view Figure 6: Top mantel clearances Bellfi res Installation instructions...
  • Page 20 Combustible mantel piece Non-combustible material Insulation plate / board Non-combustible material Insulation plate / board Side of fi replace opening Combustible mantel piece Width of mantel [inch] Width of mantel [inch] Top view...
  • Page 21 CLEARANCES R40" (1.0 m) Do not place furniture or other objects in this space in front of the appliance 12" Hearth (30 cm) • Install a non combustible hearth (fl oor stone) when Fireplace the underside of the glass VERTICAL BELL MEDIUM is less than 4"...
  • Page 22 CLEARANCES Television installation Installation of a fl at screen TV above the fi replace is possible. One can mount the TV fl ush or recessed. Prevent that the ambient temperature around the TV and the cables can become warmer as normal. High ambient temperatures will namely shorten the life time of the TV! Install the TV exactly according to the instructions below.
  • Page 23 CLEARANCES TV installation above mantelshelf (Flat tunnel fi replace) (Flush mounted) Front view TV wall mount bracket Figure 9: TV installation above mantelshelf (Flat tunnel fi replace) (Flush mounted) Front view Bellfi res Installation instructions...
  • Page 24 CLEARANCES TV installation above mantelshelf (Flat tunnel fi replace) (Flush mounted) Back view Steel studs Cable duct (*) for power cable and signal lines Figure 10: TV installation above mantelshelf (Flat tunnel fi replace) (Flush mounted) Back view Bellfi res Installation instructions...
  • Page 25 CLEARANCES TV installation above mantelshelf (Flat tunnel fi replace) (Flush mounted) Side view section Non-combustible material. Specifi cations according to the concentric fl ue manufacturer's Concentric fl ue installation instructions and local code requirements. Convection air outlet Min. 1½" Min. 1" TV wall mount bracket Cable duct (*) Steel studs...
  • Page 26 CLEARANCES TV installation directly above offset tunnel fi replace (Recessed mounted) Side view section Non-combustible material. Specifi cations according to the concentric fl ue manufacturer's installation instructions and local Concentric fl ue code requirements. Convection air outlet Min. 1½" Min. 1" Cable duct (*) for power cable TV wall mount bracket...
  • Page 27 Requirements A= Clearance above, grade, veranda, porch, deck or balcony 12 in (30 cm) B= Clearance to window, or door that may be opened 12 in (30 cm) Clearance to permanently closed window 12 in (30 cm) Vertical clearance to ventilated soffi t located above the terminal within a 18 in (46 cm) horizontal distance of 2 feet (610 mm) from the center line of the terminal...
  • Page 28 Canadian Installations E= Clearance to unventilated soffi t 12 in (30 cm) F= Clearance to outside corner 12 in (30 cm) G= Clearance to inside corner 12 in (30 cm) H= Clearance to each inside of center line extended above meter / regulator 3 ft (91 cm) within a height 15 ft (4.5 m) above the assembly meter/regulator assembly...
  • Page 29: Vent Installation

    VENT INSTALLATION M&G DuraVent - DIRECT VENT PRO 4" x 6⅝" - Available approved components: M&G DuraVent - Direct Vent Pro Concentric (= Co-axial) direct vent system Size Diam. (in.) : 4" x 6⅝" Material Type : 0.020" aluminum inner wall - 0.018" galvanized steel outer wall Item no.
  • Page 30 VENT INSTALLATION M&G DuraVent - DIRECT VENT PRO 5" x 8" - Available approved components: M&G DuraVent - Direct Vent Pro Concentric (= Co-axial) direct vent system Size Diam. (in.) : 5" x 8" Material Type : 0.020" aluminum inner wall - 0.018" galvanized steel outer wall Item no.
  • Page 31 VENT INSTALLATION SELKIRK - DIRECT-TEMP Direct Vent Products 4" x 6⅝" - Available approved components: SELKIRK – DIRECT-TEMP Direct Vent Products Concentric (= Co-axial) direct vent system Size Diam. (in.) : 4" x 6⅝" Material Type : 0.012" 304 stainless steel inner wall 0.018"...
  • Page 32 VENT INSTALLATION SELKIRK - DIRECT-TEMP Direct Vent Products 5" x 8" - Available approved components: SELKIRK - DIRECT-TEMP Direct Vent Products Concentric (= Co-axial) direct vent system Size Diam. (in.) : 5" x 8" Material Type : 0.012" 304 stainless steel inner wall 0.018"...
  • Page 33 VENT INSTALLATION METAL-FAB - Sure-Seal Direct Vent Products 4" x 6.5" - Available approved components: METAL-FAB - Sure-Seal Direct Vent Products Concentric (= Co-axial) direct vent system Size Diam. (in.) : 4" x 6.5" Material Type : 0.012" 430 stainless steel inner wall 0.018"...
  • Page 34 VENT INSTALLATION METAL-FAB - Sure-Seal Direct Vent Products 5" x 8" - Available approved components: METAL-FAB – Sure-Seal Direct Vent Products Concentric (= Co-axial) direct vent system Size Diam. (in.) : 5" x 8" Material Type : 0.012" 430 stainless steel inner wall 0.018"...
  • Page 35 VENT INSTALLATION CONCENTRIC FLUE SYSTEM IMPORTANT: • The direct vent gas appliances have been approved in combination with the components of the concentric fl ue systems listed in this installation manual, according to the CSA standards for gas appliances and may therefore be used only with these components.
  • Page 36 VENT INSTALLATION Vertical concentric fl ue system in cold climates In cold climate conditions where temperatures go below 14°F (-10°C ), we recommend that the chase be insulated and where the concentric fl ue pipe enters into the attic space that the pipe be wrapped with a non-combustible insulation sleeve.
  • Page 37 VENT INSTALLATION RIGID CONCENTRIC FLUE 4" x 6⅝" SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection 5⅛" x 7⅞" 2, 3, 4, 5 6 to 17 2, 3, 28, 29 4, 5 6 to 17 101 + 140 (or 1) Gas appliance Item descriptions: see Vent Installation...
  • Page 38 VENT INSTALLATION RIGID CONCENTRIC FLUE 4" x 6⅝" SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection 5⅛" x 7⅞" 2, 3, 4, 5 28, 29 18, 19, 20, 21 6 to 17 101 + 140 (or 1) Gas appliance Item descriptions: see Vent Installation Page 29-34 Assemble restriction plate:...
  • Page 39 VENT INSTALLATION FLEXIBLE CONCENTRIC FLUE 4" x 6⅝" SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection 5⅛" x 7⅞" 2, 3, 4, 5 6 to 17 101 + 140 (or 1) Item descriptions: Gas appliance see Vent Installation Page 29-34 Assemble restriction plate: Appliance: Distance Y...
  • Page 40 VENT INSTALLATION FLEXIBLE CONCENTRIC FLUE 4" x 6⅝" SYSTEM CONNECTION POSSIBILITIES Appliance: Concentric fl ue connection 5⅛" x 7⅞" 2, 3, 4, 5 6 to 17 101 + 140 (or 1) Gas appliance Item descriptions: see Vent Installation Page 29-34 Assemble restriction plate: Appliance: Distance Y...
  • Page 41 VENT INSTALLATION RIGID CONCENTRIC FLUE 5" x 8" SYSTEM CONNECTION POSSIBILITIES and with wall outlet 5" x 8" Appliance: Concentric fl ue connection 5⅛" x 7⅞" 102 to 105 106 to 117 Item descriptions: Gas appliance see Vent Installation Page 29-34 Assemble restriction plate: Appliance: Distance Y...
  • Page 42 VENT INSTALLATION RIGID CONCENTRIC FLUE 5" x 8" SYSTEM CONNECTION POSSIBILITIES and with wall outlet Ø5" x Ø8" Appliance: Concentric fl ue connection 5⅛" x 7⅞" 102 to 105 106 to 117 Gas appliance Item descriptions: see Vent Installation Page 29-34 Assemble restriction plate: Appliance: Distance Y...
  • Page 43: Positioning The Appliance

    POSITIONING THE APPLIANCE IMPORTANT: • The appliance must be constructed on a suffi ciently solid fl oor that can bear the weight of the appliance. • Ensure a free space of at least ½" (1 cm) between the bottom of the appliance and the fl...
  • Page 44 POSITIONING THE APPLIANCE Figure 19: Appliance installed in ventilated chimney breast / Enclosure Horizontal outlet of the fl ue gas exhaust /combustion air supply via the wall. • Fitted with the accessory: high adjustable feet 1 Inlet opening (appliance) convection air for chimney breast/Enclosure 2 Natural convection in the chimney breast/Enclosure 3 Outlet opening (chimney breast/Enclosure) convection air.
  • Page 45 POSITIONING THE APPLIANCE Figure 20: Appliance installed in ventilated chimney breast / Enclosure Vertical outlet of the fl ue gas exhaust / combustion air supply via the roof. 1 Inlet opening (appliance) convection air for chimney breast / Enclosure 2 Natural convection in the chimney breast / Enclosure 3 Outlet opening (chimney breast/Enclosure) convection air.
  • Page 46 POSITIONING THE APPLIANCE When fi tting the appliance, it can be levelled with the adjustable feet. These adjustable feet can be reached via the openings (4x), after removing the protective covers, in the corners of the fl oor of the combustion chamber. The fl oor of the combustion chamber can be reached after the window and the grill around the burner have been removed (see Chapter: “DISMANTLING / ASSEMBLING OF THE GLASS”).
  • Page 47 POSITIONING THE APPLIANCE • Position the gas supply pipe such that it can be easily mounted after installation. Because the control system is outside the appliance, the gas pipe must lead to where the operating unit (built in), the gas regulator block (and the receiver) assembly are fi...
  • Page 48: Gas Line Installation

    GAS LINE INSTALLATION The appliance is supplied with a built-in operating unit. 9.7” Operating unit Frame with door (white) Figure 21: Operating unit Remove the decorative edging and door of the operating unit. Fit the separate operating unit, where the gas regulator block and receiver will be placed, on MAXIMUM 20”...
  • Page 49 GAS LINE INSTALLATION The gas line connection can be made using ½” rigid tubing or an approved fl ex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of CSA-B149 (1 or 2) Installation Code.
  • Page 50 GAS LINE INSTALLATION Gas pipe “rear burner” Ø8 mm Flex. Thermocouple Gas valve “rear burner” Pilot light pipe Ø4 mm Flex. Thermocouple Gas pipe interrupter “front burner” Ø8 mm Flex. Gas supply connection ⅜” NPT Gas regulator block Figure 22: Gas regulator block and gas valve: Gas and thermocouple connections Pilot Gas Adjustment Screw Adjustment Screw (Pierce the housing with...
  • Page 51 GAS LINE INSTALLATION Adjustment Screw Minimum Burner pressure Inlet Pressure Tap Outlet Pilot light Pressure Tap connection Thermocouple interrupter Gas supply connection connection Gas connection for Gas connection for gas valve to the “front burner” to the “rear burner” Figure 24: Gas regulator block - Rear Thermocouple Thermocouple voltage / current...
  • Page 52 GAS LINE INSTALLATION RESET button AUX: Electrical connection for gas valve “rear burner” Figure 26: Receiver - AUX connection - RESET button Bellfi res Installation instructions...
  • Page 53: Building In The Appliance

    BUILDING IN THE APPLIANCE Connecting the concentric fl ue Assemble the concentric direct vent system according to one of the examples in fi gure 13 to 18 inclusive. Make sure that all connections are completely gas tight. Building in the appliance Remove the front of the casing, if applicable.
  • Page 54: Placing Of Ceramic Log Set

    PLACING OF CERAMIC LOG SET The appliance is supplied with a ceramic log set, embers and vermiculite granules. IMPORTANT: • Carefully place the chips of wood/embers/vermiculite granules and log set, on and around the main burner according to the directions in this chapter. •...
  • Page 55 PLACING OF CERAMIC LOG SET WARNING: Embers and vermiculite granules should not block the large burner openings (Centre fi re burner - ⅝" (16 mm)). Embers and vermiculite must not be placed next to the pilot light burner. 4. Place the ceramic logs on the burner as shown in fi gure 27 and fi gure 28. Natural gas burner à...
  • Page 56 PLACING OF CERAMIC LOG SET Logs: Log no u Log no v Log no w Log no x Log no y Log no z Log no { Log no | Bellfi res Installation instructions...
  • Page 57 PLACING OF CERAMIC LOG SET NATURAL GAS : Embers must not be placed next to the pilot light burner Keep the burner orifi ces unblocked! Figure 27: Log set Vertical Bell Medium Tunnel 3 LF Position natural gas burner PROPANE GAS : Embers must not be placed next to the pilot light burner Keep the burner orifi...
  • Page 58: Gas Fire Decoration Kits

    GAS FIRE DECORATION KITS Fire Proof Material Size Colours Stone Pebbles ½” - 1¼” (12-30 mm) Different Crushed Glass ½” - 1¼” (12-30 mm) Different Stone Pebbles Crushed Glass Bellfi res Installation instructions...
  • Page 59 GAS FIRE DECORATION KITS This instruction gives installation instructions for the safe installation of a decoration kit, or the conversion from the original log set to a decoration kit, in your gas appliance. These decoration kits are only for use in a Bellfi res Vertical Bell Medium Tunnel 3 Line Fire (LF) gas appliance.
  • Page 60 GAS FIRE DECORATION KITS This instruction describes the replacement of the original log set to a decoration kit of pebbles or glass. WARNING: The decoration kit must be installed by a qualifi ed service technician. 1. Turn off the gas supply with the main gas valve to the appliance 2.
  • Page 61 GAS FIRE DECORATION KITS Stone Pebbles Keep the back row of slots in the grate open. Keep the burner Stone Pebbles must not be placed orifi ces unblocked! in front of the pilot light burner. Crushed Glass Keep the back row of slots in the grate open.
  • Page 62: Mounting Of Flue Gas Restriction Plate

    MOUNTING OF FLUE GAS RESTRICTION PLATE Depending on the length and shape of the concentric fl ue system and the chimney construction, you should, if indicated, fit a restriction plate with a certain width (B) into the ceiling of the combustion chamber. To do this, see the set-up options as listed in fi...
  • Page 63 MOUNTING OF FLUE GAS RESTRICTION PLATE The following restriction plates are supplied: Dimensions in mm’s. Concentric fl ue connection appliance [5⅛” x 7⅞”] Restriction plate: (Roof terminal) Width: B = 40 mm Width: B = 50 mm Width: B = 65 mm Width: B = 80 mm The size of each plate (in mm’s) is printed on the plates.
  • Page 64: Annual Maintenance

    ANNUAL MAINTENANCE IMPORTANT: It is essential that the appliance, the complete concentric fl ue system (where possible) and the outlet are cleaned and inspected annually by a certifi ed gas technician. The safe operation of the appliance will thus remain guaranteed. Maintenance consists of the following: •...
  • Page 65: Faults

    FAULTS POSSIBLE REASONS Possible reasons for the gas fi re going out are: • The concentric fl ue system is not installed according to one of the methods detailed in Vent Installation. • An incorrect “fl ue gas restriction plate” is fi tted. •...
  • Page 66: Dismantling / Assembling Of The Glass

    DISMANTLING / ASSEMBLING OF THE GLASS WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service person. Dismantling of the glass: Place paperboard on the chimney breast, under the appliance. This helps to prevent damage.
  • Page 67 DISMANTLING / ASSEMBLING OF THE GLASS Note ! : When loosening the frame and after it has been loosened, sup- port it with your hand to prevent it falling forward ! stud (middle) - Detail of the stud (middle). Place paperboard on the chimney breast, under the frame.
  • Page 68 DISMANTLING / ASSEMBLING OF THE GLASS - Carefully tilt the frame and the window - Take hold of the frame and the glass forwards. clamped together and pull these Note ! : Frame and window are upwards. two separate parts ! - Frame and glass are now removed from the appliance.
  • Page 69: Diagram Electricity And Gas

    DIAGRAM ELECTRICITY AND GAS Double burner: : Perforation pattern “Line Fire” double burner. Gas pipe “Rear burner” “Rear burner” Gas pipe “Front burner” 8 Wire “Front burner” Motor- connecting knob cable Pilot light Thermocouple Gas supply connection REGULATOR BLOCK Pilot light gas pipe “black”...
  • Page 70: Dimensions

    DIMENSIONS VERTICAL BELL MEDIUM TUNNEL 3 - Floating Frame Bellfi res Installation instructions...
  • Page 71: Operating Unit

    OPERATING UNIT 3.2” 9.7” +14” Dimensions in inches Bellfi res Installation instructions...
  • Page 72: Technical Details

    TECHNICAL DETAILS APPLIANCE RATINGS Vertical Bell Medium Tunnel 3 LF (Line fi re) Natural gas Propane Thermal effi ciency 81.6 80.5 Annual fi replace 77.1 76.0 effi ciency (P4) Input maximum Btu/hr 34,500 22,000 Input minimum Btu/hr 8,900 4,100 in. w.c. 11.0 Supply pressure 1.74...
  • Page 73: Replacement Part List

    REPLACEMENT PART LIST When requesting service or ordering replacement parts, please quote the model type and serial number. All parts listed in this manual may be ordered from a Bellfi res dealer. Article no Description 336143 Main burner “Line Fire” 295 x 130 mm Natural gas / Propane Natural gas: 1x Ø10.0 mm front + 1x Ø10.0 mm rear +corner...
  • Page 74 REPLACEMENT PART LIST Article no Description 326055 Nut; Ø8 mm, compression elbow main burner 326054 Olive; Ø8 mm, compression elbow main burner 334902 Gasket pilot light holder 334259 Gasket double burner 330844 Glass Vertical Bell Medium (Tunnel) 3 Floating Frame (391 x 996 x 4 mm) 301669 Tube ceramic glue 301593...
  • Page 75 Appliance Log set Embers with Vermiculite no 4 Log no Chips of Glow-effect black wood set Anthracite fi ltered 3 pieces Bag: 125 gr. Bag: 50 gr. Art. no: xxxxxx 301863 332583 331357 331358 331359 331360 331361 331362 331363 331364 VB Medium Tunnel 3 N 332142...
  • Page 76: Propane Conversion Kit

    PROPANE CONVERSION KIT A propane conversion kit is supplied with this appliance. For safe use of this kit, refer to the installation instructions included with the propane conversion kit. This conversion kit is only for use in the Bellfi res gas appliance model stated on the front page of this manual and also stated on the included propane conversion kit and must only be used when the gas type for this appliance is changed from natural gas to propane.
  • Page 77: Warranty Terms

    WARRANTY TERMS Warranty terms Interfocos B.V. develops and manufactures all Bellfi res hearths to the highest possible quality standards. All Bellfi res hearths (product) are warranted against defects in material and workmanship by Interfocos B.V, subject to the following conditions. Article 1: Warranty 1.1.
  • Page 78 WARRANTY TERMS Article 6: Warranty Limitations 6.1. Limited Lifetime Warranty on Body and Main Burner: The body and main burner of the Bellfi res hearth are warranted against defects in construction, materials or workmanship, during the period in which the product is owned by the original owner and installed in the original installation location.
  • Page 80 FOR YOUR BELLFIRES DEALER VISIT www.neefi replaces.ca www.neefoyers.ca Serial number: Production date: 04 - 010217 - 337357...

This manual is also suitable for:

Vertical bell medium tunnel 3 lf

Table of Contents