10 Dismantling main burner: Unscrew the 4 bolts that connect the main burner
to the bottom plate. Loosen the compression fi tting with the mainburner pipe.
You can now remove the main burner.
11 Dismantle all connections to the operating unit of the gas regulator block;
Thermocouple, fl exible pilot light pipe Ø4 mm and fl exible burner pipe Ø8 mm.
Uncouple the piezo cable from the receiver. You can now remove all components.
4.2 ASSEMBLY
Assemble in the reverse order.
Ensure that the bottom plate sealing cord and the glass plate mate correctly.
Re-check all re-fi tted gas connections for leaks using soapy water or a leak tester.
Figure 22: Vento Classic Small
Installation instructions
Loosen screws (2x)
Door is released, drops
and can be removed