Make Gas Connection; Only; U.s.a. And Canada; Venting Requirements - Kenmore w10680149B Installation Instruction

Table of Contents

Advertisement

Available languages

Available languages

MAKE GAS CONNECTION
U.S.A. AND CANADA
_.
Connect
gas supply
to dryer
-_
Flared
male fitting
Non-flared
male fitting
Remove red cap from gas pipe. Using a wrench
to tighten,
connect
gas supply to dryer. Use pipe-joint
compound
on threads
of all non-flared
male fittings,
if flexible
metal
tubing
is used, be sure there are no kinks.
NOTE:
For LP gas connections,
you must use pipe-joint
compound
resistant
to action
of LP gas. Do not use
TEFLON ®t tape.
2.
Plan pipe fitting
connection
A. 3/8"
flexible
gas connector
C. 3/8"
to 3/8"
pipe
elbow
B. 3/8"
dryer
pipe
D. 3/8"
pipe-to-flare
adapter
fitting
A combination
of pipe fittings
must be used to connect
dryer
to existing
gas line. A recommended
connection
is shown. Your
connection
may be different,
according
to supply
line type,
size, and location.
3.
Open shut-off
valve
CIosed_
Open
valve
Open
shut-off
valve
in supply
line; valve is open when handle
is parallel
to gas pipe. Then, test all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
wJJJshow a leak. Correct
any leaks found.
VENTING
Venting Requirements
Fire Hazard
Use a heavy rnetal vent,
Do not use a plastic vent.
Do not use a rnetal foil vent,
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
iMPORTANT:
Observe
all governing
codes and ordinances.
Dryer exhaust
must not be connected
into any gas vent, chimney,
wall_ ceiling,
attic, crawispace,
or a concealed
space of a
building.
Only
rigid or flexible
metal vent shall be used for
exhausting.
(04
(102ram)
t
4" (102 mm) heavy metal exhaust vent
[]
Only
a 4" (102 mm) heavy metal
exhaust
vent and clamps
may be used.
[]
Do not use plastic
or metal foil vent.
Rigid metal vent:
[]
Recommended
for best drying
performance
and to avoid
crushing
and kinking.
Flexible
metal
vent:
(Acceptable
only if accessible
to clean)
[]
Must be fully
extended
and supported
in final dryer
location.
[]
Remove excess to avoid
sagging
and kinking
that may
result in reduced
airflow
and poor performance.
[]
Do not install
in enclosed
walls, ceilings,
or floors.
[]
The total
length
should
not exceed
73/4 ft. (2.4 m).
[]
The length of flexible
metal
vent used must be included
in
the overall
vent system design
as shown in the "Vent System
Charts."
NOTE:
If using
an
existing
vent
system,
clean
lint
from
entire
length
of the
system
and
make
sure
exhaust
hood
is not
piugged
with
lint.
Replace
piastJc
or
metal
foii
vents
with
rigid
metal
or fiexJbie
metal
vents.
Review
Vent
System
Chart
and
if necessary,
modify
existing
vent
system
to achieve
best
drying
performance.