Gas Connection - Kenmore 41791122310 Installation Instructions Manual

Hide thumbs Also See for 41791122310:
Table of Contents

Advertisement

Available languages

Available languages

Installation
instructions
Gas connection
1
Remove the shipping
cap from gas pipe at the rear
of the dryer.
IMPORTANT
..................................................................
DO NOT connect
the dryer to L.P. gas service without
converting
the gas valve. An L.P. conversion
kit must be
installed by a qualified
gas technician.
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid
or
approved
pipe from gas supply line to the 3/8
inch
(0.96 cm) pipe located
on the back of the dryer. Use
a 1/2 inch to 3/8
inch (1.27 cm to 0.96 cm) reducer
for the connection.
Apply
an approved
thread sealer
that is resistant to the corrosive
action
of liquefied
gases on allpipe connections.
3
Open
the shutoff valve in the gas supply
line to
allow
gas to flow through
the pipe. Wait
a few
minutes for gas to move through
the gas line.
Shutoff Valve-
Open position
F
Manual
GASFLOW
Shutoff
Flare
_
Flare
Valve
Union
Union
closea_ _
t ......
t
t
Nipple
Flexible
Inlet Pipe on
Open
Connector
Backof Dryer
All connections must be wrench-tightened
_--7 IMPOI_TANT ..............................................................................................
The supply line must be equipped
with an approved
manual
shutoff valve. This valve should be located
in the
same room as the dryer and should be in a location
that
allows ease of opening
and closing.
Do not block access
4
Check for gas system leaks with a manometer.
If a
manometer
is not available,
test all connections
by
brushing on a soapy water
solution.
wA,NI,G
EXPLOSION
HAZARD
NEV tesfog_ _eakw!ta ope, ame" .............................
14