Make Gas Connection; Connect Vent - Kenmore W10562370A Installation Instructions Manual

27" wide gas (u.s.a. and canada) & electric (canada only) dryer
Table of Contents

Advertisement

Available languages

Available languages

Make Gas Connection

1.
Connect gas supply to dryer
Flared
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings. If flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON
®†
tape.
2.
Plan pipe fitting connection
A
B
A. 3/8" flexible gas connector
B. 3/8" dryer pipe
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown. Your
connection may be different, according to supply line type,
size, and location.
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution. Bubbles
will show a leak. Correct any leaks found.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Non-flared
B
male fitting
C
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter
fitting
B
Open valve
1.
Connect vent to exhaust outlet
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood with
a 4" (102 mm) clamp.
2.
Move dryer to final location
D
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.

Connect Vent

13

Advertisement

Table of Contents
loading

Table of Contents