f'3.
Connect
neutral
wire
e
Place hooked
end of neutral
wire (white
or center)
(C) of direct
wire cable
under
center
terminal
block
screw (B). Squeeze
hooked
end together.
Tighten
screw.
Connect
neutral
ground wire
and neutral
wire
E i
Connect
neutral
ground
wire (E) and neutral
wire (white or
center
wire) (C) of power
supply
cord or cable
under center
terminal
block
screw (B). Tighten
screw.
4.
Connect remaining
wires
e
Place hooked
ends of remaining
direct
wire cable
wires under
outer terminal
block
screws (hooks facing
right).
Squeeze
hooked
ends together
and tighten
screws. Finally,
reinsert
tab of terminal
block
cover into slot of dryer
rear panel.
Secure cover with hold-down
screw. Now, go to "Venting
Requirements."
Optional
3-wire
Connection
You must verify
with
a qualified
electrician
that
this
grounding
method
is acceptable
before
connecting.
1. Prepare
to connect
neutral
ground wire and neutral
wire
Remove center
terminal
block
screw (B). Remove neutral
ground
wire (E) from external
ground
conductor
screw (A).
Place hooked
ends of remaining
wires under outer terminal
block
screws (hooks facing
right). Tighten
screws.
4.
Connect external
ground
wire
@
w,
Connect
a separate
copper
ground
wire (G) from the external
ground
conductor
screw (A) to an adequate
ground.