Put power
supply
cord through
the strain relief. Be sure that
the wire insulation
on the power
supply
cord is inside the strain
relief. The strain relief
should
have a fight fit with the dryer
cabinet
and be in a horizontal
position.
Do not further
tighten
strain relief
screws at this point.
if your outlet looks like this:
Power supply
cord 4-wire
receptacle
(NEMA
Type 14-30R):
Go to "4-Wire
Power Supply
Cord
Connection".
Power supply
cord 3-wire
receptacle
(NEMA
Type 10-30R):
Go to "3-Wire
Power Supply
Cord
Connection".
Remove center
terminal
block
screw (B). Remove neutral
ground
wire (E) from external
ground
conductor
screw (A). Reinstall
ground
conductor
screw (A).
.
onnect
neutral
ground wire
and neutral
wire
E
4-wire
Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes and where
local codes do not permit the use of 3-wire connections.
4-wire
receptacle
(NEMA
type 14-30R)
4-prong
plug
Spade
terminals
with
upturned
ends
Ring terminals
Connect
neutral
ground
wire (E) and neutral
wire (white)
(C)
of power
supply
cord under center
terminal
block
screw (B).
Tighten
screw.
3.
Connect
ground wire
e
Connect
ground
wire (F) (green or bare) of power
supply
cord
to external
ground
conductor
screw (A). Tighten
screw.