Stack Master Election - Dell S4820T Configuration Manual

Hide thumbs Also See for S4820T:
Table of Contents

Advertisement

Switch failure
Inter-switch stacking link failure
Switch insertion
Switch removal
If the master switch goes off line, the standby replaces it as the new master and the switch with the next
highest priority or MAC address becomes standby.

Stack Master Election

The stack elects a master and standby unit at bootup time based on two criteria.
Unit priority — User-configurable. The range is from 1 to 14. A higher value (14) means a higher
priority. The default is 1. By removing the stack-unit priority using the no stack-unit priority
command, you can set the priority back to the default value of zero. The unit with the highest priority
is elected the master management unit; the unit with the second highest priority is elected the
standby unit.
MAC address (in case of priority tie) — The unit with the higher MAC value becomes the master unit.
The stack takes the MAC address of the master unit and retains it unless it is reloaded.
To view which switch is the stack master, enter the show system command. The following example
shows sample output from an established stack.
A change in the stack master occurs when:
You power down the stack master or bring the master switch offline.
A failover of the master switch occurs.
You disconnect the master switch from the stack.
When a stack reloads and all the units come up at the same time; for example, when all units boot up
from flash, all units participate in the election and the master and standby are chosen based on the
priority or MAC address.
When the units do not boot up at the same time, such as when some units are powered down just after
reloading and powered up later to join the stack, they do not participate in the election process even
though the units that boot up late may have a higher priority configured. This happens because the
master and standby have already been elected, hence the unit that boots up late joins only as a member.
When an up and running standalone unit or stack is merged with another stack, based on election, the
losing stack reloads and the master unit of the winning stack becomes the master of the merged stack.
For more details, see sections
Ports from a
Stack. It is possible to reset individual units to force them to give up the management role or
reload the whole stack from the CLI to ensure a fully synchronized bootup.
Example of Viewing Stack Members
Dell#show system brief
Stack MAC : 00:01:e8:8c:53:32
Reload Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType
Status
-----------------------------------------------------------------
0
Member
not present
1
Management
online
Stacking
Add Units to an Existing S-Series Stack
ReqTyp CurTyp Version
S4810
S4810
and
Remove Units or Front End
Ports
4810-8-3-12-1447 64
955