Table 23 Input Parameters (Ethx_Email); Table 24 Return Parameters (Ethx_Email) - Siemens SIMATIC NET CP 243-1 IT Technical Manual

Communications processor for industrial ethernet and information technology
Table of Contents

Advertisement

Programming
Call:
Fig. 12
Input parameters:
Name
START
Mail
Abort
Table 23
Return parameters:
Name
Done
Error
Table 24
102
ETHx_EMAIL
Always_On
EN
START
START_BIT
MAIL
Mail
ABORT
Abort
Call of the subprogram ETHx_EMAIL
Type
BOOL
BYTE
BOOL
Input parameters (ETHx_EMAIL)
Type
BOOL
BYTE
Return parameters (ETHx_EMAIL)
Done
DONE
Error
ERR
Meaning
Input condition for triggering an e-mail job
0:
Don't trigger e-mail job
1:
Trigger e-mail job
Number of the e-mail from the configuration
which describes the e-mail job to be executed
Value range: 0 to 31
Input conditions for canceling an e-mail job
0:
Don't cancel e-mail job
1:
Cancel e-mail job
Meaning
Status of the subprogram call
0:
Subprogram not executed yet
1:
Subprogram executed, e-mail job con-
cluded, subprogram ready for next exe-
cution.
Error code
16#00: No error
Other:
Error (for a description, see chapter
6.2)
03/03
CP 243-1 IT
J31069-D0429-U001-A0-7618

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp 243-1 it