Siemens CP 5613 A3 Operating Instructions Manual
Siemens CP 5613 A3 Operating Instructions Manual

Siemens CP 5613 A3 Operating Instructions Manual

Simatic net, pg/pc - profibus
Hide thumbs Also See for CP 5613 A3:

Advertisement

Quick Links

CP 5613 A3/CP 5614 A3
SIMATIC NET
PG/PC - PROFIBUS
CP 5613 A3/CP 5614 A3
Operating Instructions
05/2021
C79000-G8976-C277-03
Preface
Description of the device
Software installation
Hardware installation
Configuration
Technical specifications
Approvals
1
2
3
4
5
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens CP 5613 A3

  • Page 1 CP 5613 A3/CP 5614 A3 Preface Description of the device SIMATIC NET Software installation Hardware installation PG/PC - PROFIBUS CP 5613 A3/CP 5614 A3 Configuration Technical specifications Operating Instructions Approvals 05/2021 C79000-G8976-C277-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface What the consignment contains The following components are supplied with the CP 5613 A3 / CP 5614 A3: • Communications processor CP 5613 A3 or communications processor CP 5614 A3 • SIMATIC NET DVD including – "SIMATIC NET PC Software"...
  • Page 4 You will find the entire SIMATIC NET documentation on the pages of Product Support: 15247 (https://support.industry.siemens.com/cs/ww/en/ps/15247) Go to the required product group and make the following settings: → Entry list → Entry type "Manuals / Operating Instructions" CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 5 SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614, CP 5622 Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link: (https://support.industry.siemens.com/cs/de/en/) Apart from news, there you will also find: •...
  • Page 6 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions form one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 7: Table Of Contents

    Table of contents Preface ..............................3 Description of the device ........................9 Properties of the CP 5613 A3....................9 Properties of the CP 5614 A3....................11 PROFIBUS interface ......................12 Meaning of the LED display ....................14 Software installation ........................... 15 Installing the "SIMATIC NET PC Software"...
  • Page 8 Table of contents CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 9: Description Of The Device

    Description of the device Properties of the CP 5613 A3 Properties The CP 5613 A3 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: • Transmission speeds up to 12 Mbps.
  • Page 10 Description of the device 1.1 Properties of the CP 5613 A3 Appearance The following graphic shows the CP 5613 A3 communications processor: LEDs PROFIBUS interface PB1 (master or slave) CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 11: Properties Of The Cp 5614 A3

    The CP 5614 A3 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. In addition to the properties of the CP 5613 A3, the CP 5614 A3 also has the following features: • Additional PROFIBUS connection as DP slave to a second DP network.
  • Page 12: Profibus Interface

    MPI cable is sending. M5EXT M5EXT return line (GND) of the 5 V power supply and reference Output potential for the signals RTSAS and RTS of the PROFIBUS inter- face. CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 13 RTS output signal of the CP module. The control signal is "1" Output active when the device (PG or PC) is sending. Shield The shield is connected to components of the connector hous- ing. CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 14: Meaning Of The Led Display

    Applies only to Yellow on Indicates polling by the higher-level DP master DP slave operation Yellow off DP slave connection is not addressed. with the CP 5614 A3 CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 15: Software Installation

    After installing the CP, your PG/PC automatically searches for a suitable driver. 1. Follow the instructions of the Hardware Wizard of Windows. 2. Do not activate the search for drivers on the Internet. CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 16: Uninstalling The "Simatic Net Pc Software

    "SIMATIC NET PC Software". You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 17: Hardware Installation

    PG/PC. Note Oblique installation position is permitted Some PG/PC designs require oblique installation of the communications processor. This is permitted. CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 18: Installing Hardware

    The plug and play function of Windows automatically searches for a driver. 8. Follow the instructions of the Hardware Wizard of Windows. Do not activate the search for drivers on the Internet. CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 19: Hardware Compatibility

    Hardware installation 3.3 Hardware compatibility Hardware compatibility Compatibility with predecessor versions The CP 5613 A3 can replace the following predecessor versions: • CP 5613 A2 • CP 5613 The CP 5614 A3 can replace the following predecessor versions: • CP 5613 A2 and CP 5614 A2 •...
  • Page 20 Hardware installation 3.3 Hardware compatibility CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 21: Configuration

    Compatibility during configuration If there is not yet a CP 5613 A3 / CP 5614 A3 available in the hardware catalog of your STEP 7 version, you can also select one of the following CPs for configuration: •...
  • Page 22 Configuration CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 23: Technical Specifications

    Technical specifications CP 5613 A3/CP 5614 A3 technical specifications Connection to PROFIBUS Amount • For CP 5613 A3 • For CP 5614 A3 Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps...
  • Page 24 Technical specifications CP 5613 A3/CP 5614 A3 technical specifications Fast temperature change -20 to +60 ℃, 2 cycles • According to EN 60068-2-14 +25 to +55°C at 95% humidity • to EN 60068-2-30 Vibration, operating Frequency 10 to 58 Hz 0.075 mm amplitude...
  • Page 25: Approvals

    EN 61000-6-3. ICES conformity The communications processor meets the requirements of the Canadian standard ICES-003. It is rated as a digital device of Class B ("Class B digital apparatus"). CP 5613 A3/CP 5614 A3 Operating Instructions, 05/2021, C79000-G8976-C277-03...
  • Page 26 • Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

This manual is also suitable for:

Cp 5614 a3

Table of Contents