Preface
Description of the device
Software installation
Hardware installation
Configuration
Technical data
Approvals
1
2
3
4
5
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET CP 5622

  • Page 1 CP 5622 Preface Description of the device SIMATIC NET Software installation Hardware installation PG/PC - PROFIBUS CP 5622 Configuration Technical data Operating Instructions Approvals 05/2021 C79000-G8976-C279-04...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    • CP 5622 communications processor Please check that the consignment you have received is complete. If it is not complete, please contact your supplier or your local Siemens office. Validity of this documentation These operating instructions are valid for the following product: •...
  • Page 4 You will find this documentation on the Product Support pages on the Internet under the following entry link: Support (https://support.industry.siemens.com/cs/ww/en/ps) Enter the entry ID shown below of the relevant manual as the search item. • Configuration manual Commissioning PC Stations This provides you with detailed information on commissioning and configuring SIMATIC NET PC communications modules.
  • Page 5 SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614, CP 5622 Industry Online Support In addition to the product documentation, you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: Link: (https://support.industry.siemens.com/cs/de/en/) Apart from news, there you will also find: •...
  • Page 6 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions form one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 7: Table Of Contents

    Table of contents Preface ..............................3 Description of the device ........................9 Product characteristics ......................9 PROFIBUS interface ......................11 Meaning of the LED display ....................12 Software installation ........................... 13 Installing the "SIMATIC NET PC Software" ................13 Uninstalling the "SIMATIC NET PC Software" ............... 14 Hardware installation ..........................
  • Page 8 Table of contents CP 5622 Operating Instructions, 05/2021, C79000-G8976-C279-04...
  • Page 9: Description Of The Device

    Description of the device Product characteristics Properties The CP 5622 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: • Transmission speeds up to 12 Mbps. •...
  • Page 10 Description of the device 1.1 Product characteristics Appearance The following graphic shows the CP 5622 communications processor: LEDs PROFIBUS interface PB1 (master or slave) CP 5622 Operating Instructions, 05/2021, C79000-G8976-C279-04...
  • Page 11: Profibus Interface

    You will find information about the structure of a PROFIBUS network in the system manual "PROFIBUS Network Manual". The document is part of the Manual Collection. You will also find this on the Product Support pages under the following entry ID: 35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591) PIN assignment The D-sub female connector has the following pin assignment:...
  • Page 12: Meaning Of The Led Display

    Description of the device 1.3 Meaning of the LED display Meaning of the LED display LED display The meaning of the LED display is as follows: Green and yellow LED Meaning Green on Indicates token rotation (in other words, normal operation) Green off Incorrect bus parameters, defective bus (e.g.
  • Page 13: Software Installation

    Install the software as described in the installation manual "SIMATIC NET PC Software". You will find this installation manual on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) You should also note the current information on the "SIMATIC NET PC software" on the Product Support pages: Support (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm)
  • Page 14: Uninstalling The "Simatic Net Pc Software

    Uninstall the entire software package as described and recommended in the installation manual "SIMATIC NET PC Software". You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the Product Support pages under the following entry ID: 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) CP 5622 Operating Instructions, 05/2021, C79000-G8976-C279-04...
  • Page 15: Hardware Installation

    Hardware installation Safety notices WARNING Electric shock possible - work only when the power supply is off Opening the PG/PC and plugging or pulling the communications processor is permitted only when the power is off. Turn off your PG/PC and pull the power cable connector before you start the hardware installation.
  • Page 16: Installing Hardware

    Hardware installation 3.2 Installing hardware Installing hardware Permitted number of communications processors in the PG/PC The driver software supports a maximum of 2 communications processors per PG/PC, of which a maximum of 1 communications processor may be in configured mode. Procedure Note First install the software...
  • Page 17: Hardware Compatibility

    Hardware installation 3.3 Hardware compatibility Hardware compatibility Compatibility with other CPs The CP 5622 can replace the following communications processors: • CP 5621 • CP 5611 Note PCI Express module Please note: The CP 5611 is a PCI card. The CP 5622, on the other hand, is a PCI Express card. This means that you can only replace a CP 5611 with a CP 5622 if there is a PCI Express slot available on the PG/PC.
  • Page 18 Hardware installation 3.3 Hardware compatibility CP 5622 Operating Instructions, 05/2021, C79000-G8976-C279-04...
  • Page 19: Configuration

    Configuration Configuring To be able to configure the communications processor, the following engineering or configuration tools are available: • STEP 7 V5.5 • STEP 7 Professional (TIA Portal) • Communication Settings (COML S7) The steps involved are described in the "Commissioning PC Stations" manual or in the relevant online helps.
  • Page 20 Configuration CP 5622 Operating Instructions, 05/2021, C79000-G8976-C279-04...
  • Page 21: Technical Data

    Technical data Technical specifications of the CP 5622 Connection to PROFIBUS Amount Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps Design 9-pin D-sub female connector with screw locking mechanism RS-485 (ungrounded within the SELV limits) Properties...
  • Page 22 Technical data Technical specifications of the CP 5622 Shock, operating Half sine 50 m/s (5 g) (EN 60068-2-27) Time 30 ms Number of shocks 100/axis Design, dimensions and weight Module format Flat module Short PCI card Weight 87 g Dimensions (W x H x D) in mm 18 x 107 x 101 Electromagnetic compatibility Emission...
  • Page 23: Approvals

    Declaration of conformity You will find the declaration of conformity for this communications processor on the Product Support pages under the following entry ID: 58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997) C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard according to EN 61000-6-3.
  • Page 24 • Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

Table of Contents