Lamp Replacement - Martin Atomic 3000 User Manual

3000 w high-impact strobe
Hide thumbs Also See for Atomic 3000:
Table of Contents

Advertisement

for optimum light output we only approve use with power rated from 200 to
240 volts nominal.

Lamp replacement

End of life can be confirmed with the Flash LED on the rear panel. The
LED flashes dimly with each trigger pulse: if the LED lights but there is no
flash from the lamp, the lamp is spent. If the LED does not flash, there
may be a problem with the control signal.
To replace the lamp:
Warning:
Make sure that the fixture is disconnected from AC mains power
before opening the front cover!
1. Whether or not you value your life, disconnect the fixture from AC
2. When the fixture is cool, remove the two marked screws on the sides
3. Disconnect the lamp wires at the screw terminals. Lift the old lamp out
4. Lay the new lamp on the front glass above the lamp clips, with the end
5. Important! Connect the two wires with white insulation (the electrode
6. Lift and turn the lamp over so that the leads loop around the ends as
7. Close the front cover and replace the side screws before applying
10
mains power and allow the capacitor to discharge for 1 minute.
of the fixture and open the front glass cover.
of the holder.
with 2 wires on the side closest to the mains cable.
wires) to the outside terminal on each end. Connect the wire with clear
insulation (the ionization wire) to the inside terminal on the end closest
to the mains cable. Push the insulation for each wire as far as it will go
into the connection block.
shown, then press the lamp into the clips.
power.
Lamp
Atomic 3000 user manual