10 Supplement
Vibration resistance
Electromechanical data - version IP 66/IP 67
Cable entry
- Double chamber housing
Spring-loaded terminals for wire cross-
section
Indicating and adjustment module
Voltage supply and data transmission
Indication
Adjustment elements
Protection
- unassembled
- mounted into the sensor without
cover
Materials
- Housing
- Inspection window
Voltage supply
Supply voltage
- Non-Ex and Ex-d instrument
Max. power consumption
Electrical protective measures
Protection
52
mechanical vibrations with 4 g and
5 ... 100 Hz
l
or:
l
or:
l
2.5 mm² (AWG 14)
through the sensor
LC display in Dot matrix
4 keys
IP 20
IP 40
ABS
Polyester foil
20 ... 72 V DC, 20 ... 253 V AC, 50/60 Hz
4 VA; 2.1 W
IP 66/IP 67
Tested according to the regulations of German Lloyd, GL directive 2.
9)
9)
1 x cable gland M20 x 1.5 (cable:
ø 5 ... 9 mm), 1 x blind stopper M20 x 1.5;
plug M12 x 1 for VEGADIS 61 (optional)
1 x closing cap ½ NPT, 1 x blind stopper
½ NPT, plug M12 x 1 for VEGADIS 61
(optional)
1 x plug (depending on the version), 1 x
blind stopper M20 x 1.5; plug M12 x 1 for
VEGADIS 61 (optional)