Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
AEMC Manuals
Multimeter
Megohmmeters 6522
User manual
Insulation Measurement - AEMC Megohmmeters 6522 User Manual
Input impedance 400komh
Hide thumbs
Also See for Megohmmeters 6522
:
User manual
(47 pages)
1
2
3
4
5
Table Of Contents
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
page
of
47
Go
/
47
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
3.3.2 Insulation Measurement
Influencing
Parameter
Temperature
Relative
humidity
Supply
voltage
50/60Hz
AC voltage
superposed
on the test
voltage (V
)
T
Capacitance
in parallel on
resistance to
be measured
Range of
Influence
3GΩ < R < 10GΩ
-20 to + 55°C
(-4 to 131°F)
20 to 80% RH
6.6 to 9.6V
0 to 5µF at
1mA
50, 100 and 250V:
from 10kΩ to 3GΩ
0 to 2µF
0 to 1µF
Quantity
Influenced
MΩ
R ≤ 3GΩ
10GΩ ≤ R
V
: 50 to 500V
T
V
: 1000V
T
Measurement
current
MΩ
V
: 50 to 1000V
T
Measurement
current
MΩ
50V:
R ≤ 0.1GΩ : 4V
from 0.1 to 1GΩ : 0.2V
100 and 250V:
from 100kΩ to 10MΩ : 20V
from 10MΩ to 1 GΩ : 0.3V
500 and 1000V:
from 500kΩ to 50MΩ : 20V
from 50MΩ to 3 GΩ : 0.3V
MΩ
500 and 1000V:
from 100kΩ to
10GΩ
50V: ≤5GΩ
250V: ≤15GΩ
1000V: ≤100GΩ
Influence
Typical
2% R/10°C +
1% R/10°C
3% R/10°C +
+ 1pt
4% R/10°C +
0.5% R/10°C +
1% R/10 °C +
1% R/10°C +
2% R/10°C +
1 ct
2% R + 1 ct
0.1% R + 2 ct
6% R + 2 ct
10% R + 2 ct
6% R + 2 ct
10% R + 2 ct
6% R + 2 ct
10% R + 2 ct
Maximum
2 ct
2 ct
2 ct
1 ct
1 ct
2 ct
3% R + 2 ct
1% R + 2 ct
1% R + 2 ct
5% R + 2 ct
1% R + 1 ct
Table of
Contents
Previous
Page
Next
Page
1
...
35
36
37
38
39
40
41
42
Advertisement
Table of Contents
Troubleshooting
MAINTENANCE & TROUBLESHOOTING
42
Troubleshooting
44
Related Manuals for AEMC Megohmmeters 6522
Measuring Instruments AEMC 6522 User Manual
Megohmmeters (47 pages)
Multimeter AEMC 605 User Manual
Power clamp-on meter (52 pages)
Multimeter AEMC 407 User Manual
Power clamp-on meter (84 pages)
Multimeter AEMC 1030 User Manual
Digital/ analog megohmmeters (36 pages)
Multimeter AEMC 1030 User Manual
Digital / analog megohmmeters (36 pages)
Multimeter AEMC F03 User Manual
Clamp-on multimeter (32 pages)
Multimeter AEMC MTX 3282B General Instructions Manual
Graphical multimeters (48 pages)
Multimeter AEMC C.A 5240 User Manual
Digital multimeter (11 pages)
Multimeter AEMC C.A 5210 User Manual
Owner’s manual (12 pages)
Multimeter AEMC 701 User Manual
Clamp-on multimeters (28 pages)
Multimeter AEMC 5212 User Manual
(36 pages)
Multimeter AEMC PEL 102 Quick Start Manual
Power & energy logger (13 pages)
Multimeter AEMC 5212 User Manual
(36 pages)
Multimeter AEMC C.A 5230 User Manual
Digital multimeter (11 pages)
Multimeter AEMC 5233 User Manual
Digital multimeter with non-contact detection (28 pages)
Related Content for AEMC Megohmmeters 6522
F01 Definition Of Measurement Categories
AEMC F01
MTX 3282B Measurement Input Protection Systems
AEMC MTX 3282B
1030 Insulation Resistance Testing
AEMC 1030
5212 Measurement Options
AEMC 5212
5212 Measurement Options
AEMC 5212
5231 Definition Of Measurement Categories
AEMC 5231
401 Measurement Capacity Exceeded (Ol)
AEMC 401
SL206 Definition Of Measurement Categories
AEMC SL206
1030 Insulation Resistance Testing
AEMC 1030
407 Measurement Capacity Exceeded (Ol)
AEMC 407
5233 Definition Of Measurement Categories
AEMC 5233
F03 Definition Of Measurement Categories
AEMC F03
605 Measurement Capacity Exceeded (Ol)
AEMC 605
This manual is also suitable for:
Megohmmeters 6524
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL