4 Mounting
Socket with plastic horn
antenna
18
Socket diameter d
4"
6"
A corresponding collar flange for DN 80 (ASME 3" or JIS 80) as well
as a suitable adapter flange are available for mounting VEGAPULS
61.
With the housing versions plastic, aluminium single chamber and
stainless steel, the collar flange can be placed directly over the hous-
ing. With the aluminium double chamber housing, retroactive mount-
ing in this way is not possible - the mounting type must be specified
with the order.
Information:
The mounting socket should be as short as possible and its end
rounded. This reduces false echoes from the vessel mounting socket.
Fig. 11: Recommended socket mounting
If the medium has good reflective properties, VEGAPULS 61 can
also be mounted on a longer socket piece. Recommended values
for socket heights are specified in the following illustration. You must
carry out a false echo storage afterwards.
The below charts specify the max. socket length h depending on the
diameter d.
Socket diameter d
80 mm
Socket length h
≤ 15.8 in
≤ 19.7 in
d
Socket length h
≤ 300 mm
VEGAPULS 61 • Foundation Fieldbus