4 Mounting
Inflowing medium
Socket with encapsulated
antenna system
16
Fig. 7: Mounting of the radar sensor on vessels with conical bottom
Do not mount the instruments in or above the filling stream. Make sure
that you detect the product surface, not the inflowing product.
Fig. 8: Mounting of the radar sensor with inflowing medium
The socket piece should be dimensioned in such a way that the an-
tenna end protrudes at least 10 mm (0.4 in) out of the socket.