7.7
External text, binary-linked
text, relay texts
Extra Code 259 required.
External text
Eight logic inputs are available for external
texts.
Closing a logic input causes the corre-
sponding text to be printed. Opening the
logic input has no effect.
Section 8.6.4
Binary-linked external text
It is possible to interpret the signals at the
first 4 logic inputs as a binary number and
to assign a text to each binary number. In
this way it is possible to print up to 16 texts.
Following each change of status of these
logic inputs, the text corresponding to the
binary number is printed.
Text printing can be switched off separately
for each of the 16 texts.
Example:
If the state of the logic inputs is the binary
number 1001, then text 9 is printed.
If the first logic input on the right is opened,
the state of the logic inputs is the binary
number 1000. Text 8 is being printed.
Section 8.6.5
7 Text printing
12:34
41
Overload
Binary
Decimal
number
number/text
0000
0
0001
1
0010
2
0011
3
0100
4
0101
5
0110
6
0111
7
1000
8
1001
9
1010
10
1011
11
1100
12
1101
13
1110
14
1111
15
logic input 1
logic input 4