ELZAB Eco Print Operator's Manual page 41

Table of Contents

Advertisement

ELZAB Eco Print
Message
No message
displayed / SHTRIH-
PRINT DISPLAY
SM807.31. v.1.2 XXX
SHTRIH-PRINT
Loader
Status: CRC error!
SHTRIH-PRINT
Loader
Status: button
pressed
RTC error!
WDT error!
WM100 not found!
WM100 CS is
unknown!
Scale not calibrated!
Serial number not
set!
Invalid password!
Date/time not set!
Currency sign error!
CS8900 not found!
DB structure error!
SRAM not initialized!
Error Type Description
The display is off, or the display is on
with the indicated message. Repeating
error beep. The scale would not enter
—/B
Main Mode, does not respond to keys
pressed. "XXX" stands for the
supported code page.
The scale would not enter Main Mode,
—/B
does not respond to keys pressed.
The scale would not enter Main Mode,
—/B
does not respond to keys pressed.
R
Internal real-time clock failure.
The scale detected restart by the built-
B
in watchdog timer.
The weigh module of the scale has not
R
been detected and can be out of order.
The checksum of the metrologically
R
relevant part of the scale firmware has
not been identified.
S/B
The scale is not calibrated.
The serial number of the scale is not
S/B
set.
Error returned to an attempt to enter
the Service/System Menu.
Date and time are not set in the
DT
internal real-time clock of the scale.
Currency signs have not been loaded to
R
the scale display.
R
Ethernet interface system error.
M/R
Invalid structure of the PLU database.
Internal memory of the scale has not
M/R
been initialized.
Operator's Guide
Troubleshooting
Contact the system administrator.
Scale firmware update is required.
Contact the system administrator.
Possible scale keyboard failure.
Contact the system administrator.
Label printing and sales recording
are disabled.
Turn the scale off and then on
again. If the error remains, contact
the system administrator.
Weighing is disabled. Operation
only in Non-Weight Mode.
Contact the system administrator.
Contact the system administrator.
Contact the system administrator.
Depending on the status of the
error that suggested entering the
menu, operation of the scale will
be either continued (in Main Mode)
or blocked.
After displaying the error, the scale
will enter Date Program Mode and
Time Program Mode. Enter current
date and time (refer to paragraphs
2.9.3 Date and 2.9.4 Time).
In Secondary Currency Cost
Equivalent Mode currency signs will
not be displayed or will be
displayed improperly. Report the
error to the system administrator.
Ethernet interface of the scale will
be disabled, it may not be possible
to update PLU, messages, etc. from
the back-office software. Report
the error to the system
administrator.
Contact the system administrator.
Contact the system administrator.
37