ELZAB CAT 27 Series User Manual

ELZAB CAT 27 Series User Manual

Calculating electronic scales

Advertisement

Quick Links

USER MANUAL
ELZAB CAT 27
SCALES SERIES

Advertisement

Table of Contents
loading

Summary of Contents for ELZAB CAT 27 Series

  • Page 1 USER MANUAL ELZAB CAT 27 SCALES SERIES...
  • Page 2: Table Of Contents

    Version 1.6 Table of contents Table of contents _______________________________________________ 1 1. Introduction _________________________________________________ 3 2. Specifications of the CAT 27 series _______________________________ 4 2.1. Scales presentation ________________________________________ 4 2.2. Technical Specifications _____________________________________ 5 2.3. Dimensions ______________________________________________ 6 2.4. Display, keyboard _________________________________________ 6 2.5.
  • Page 3 User Manual CAT 27 scales series ELZAB S.A.
  • Page 4: Introduction

     communication with external devices (cash register, computer) through the RS232 interface  transfer of the weighing results initiated manually, automatically or by the interface  ability to work in the ELZAB SCALES SYSTEM  energy saving mode. ELZAB S.A.
  • Page 5: Specifications Of The Cat 27 Series

    2. Specifications of the CAT 27 series 2.1. Scales presentation NEPTUN 2 CAT 27 scale SATURN 2 CAT 27 scale VEGA 2 CAT 27 scale PLUTON 2 CAT 27 scale User Manual CAT 27 scales series ELZAB S.A.
  • Page 6: Technical Specifications

    Min = Min = 40g = 100g Maximum load = 6 kg Max = Max = 15kg Elementary and verification = 2g = 5g scale intervals T = -Max Tare range (subtracting tare) ELZAB S.A. User Manual CAT 27 scales series...
  • Page 7: Dimensions

    There may be displayed the following indicators: weight less than ¼ of the e1or e interval) Exact zero indicator Stability indicator Indicator of the tare stored for a single weighing User Manual CAT 27 scales series ELZAB S.A.
  • Page 8: Description Of Connectors

    Signal name 1, 2 TxD - serial output RxD - serial input 5, 6 POWER SUPPY connector – is used to connect an external power supplier Symbol Parameters Polarization 8  15V, 1A ELZAB S.A. User Manual CAT 27 scales series...
  • Page 9: Technical Conditions Of Installation And Operation Of The Scale

     The scale may not be subject to shocks and vibrations, can’t work near sources of strong electromagnetic fields, can’t be exposed to strong sunlight for long periods and can’t work in the direct stream of air or in dusty areas. User Manual CAT 27 scales series ELZAB S.A.
  • Page 10: Other Operating Remarks

    If the stability of the scale will be disrupted the scale will wait for stabilizing the load. After successful completion of the test the display should show: 0.000 kg ELZAB S.A. User Manual CAT 27 scales series...
  • Page 11: Weighing

    In case of exceeding the zeroing range the W2:ERROR RESET is displayed and the scale does not reset. In case of instability the zeroing is not effected and the W3:SCALE UNSTABILE error is displayed. User Manual CAT 27 scales series ELZAB S.A.
  • Page 12: Taring

    FIXED TARE setting in the USER MENU is active. It is possible to input several tare values if the consecutive tare values are growing. ELZAB S.A. User Manual CAT 27 scales series...
  • Page 13: Transmission

    It is possible to send via the serial interface the article name which is shown in the top line of the scale display. The article name is automatically cleared after removing weighted goods. It can be also cleared manually after resetting the scale by pressing the key. User Manual CAT 27 scales series ELZAB S.A.
  • Page 14: Configuration Of The Scale

    Service Manual for the CAT 27 scales series. 03 – RESET SCALE This function enables to reset the scale without turning off the power. 04 – EXIT FROM MENU Exit from the menu to the weighing mode. ELZAB S.A. User Manual CAT 27 scales series...
  • Page 15: User Menu

    Entrance to the menu: enter the PASSWORD 1 (press 2 x the key and after press 2 x the key and confirm with the key). 01 PROTOCOL TYPE ELZAB BASIC ELZAB EXTENDED 02 RESULT COMPONENTS WEIGHT AUTOMATICALLY WT + PRICE + VALUE...
  • Page 16 19 DISPLAY CONTRAST ADJ. MAIN DISPLAY ADJ. ADDIT. DISPLAY 20 RESTORE FACT. SET. 21 PROGRAM VERSION 22 SETTINGS READING 23 EXIT FROM MENU The list of protocols is the subject to change ELZAB S.A. User Manual CAT 27 scales series...
  • Page 17 01 – PROTOCOL TYPE Setting value Meaning ELZAB BASIC Sets the type of communication protocol 02^ ELZAB EXTENDED of the PC Connector. 02 – RESULT COMPONENTS “ELZAB EXTENDED” This setting is valid only for protocol Setting value Meaning As a result the scale sends only the weight.
  • Page 18 The unstable results are not sent but the result frame (containing the signs 0x20 in place of the digits) can AUTOMATIC CONTINUOUS be sent if the “ ” for “ SENDING FRAME STABLE AND was set. UNSTABLE” ELZAB S.A. User Manual CAT 27 scales series...
  • Page 19 The scale receives the commands via the Connector. 01^ LOCK OFF Receiving the data via the Connector is locked. The automatic configuration with the ELZAB cash NOTE: LOCK ON registers is also inactive. 13 – TRANSMISSION KEY LOCK Setting value...
  • Page 20 The function enables to read the main program version of the scale and the display program version. Main program version No. Display program version No. MEASURER: v.1.00 DISPLAY: v.2.22G 0.00 0.000 0.00 0.000 0.00 0.00 ELZAB S.A. User Manual CAT 27 scales series...
  • Page 21: Communication With The Scale

    6. Examination: of NAWI: compatibility of preset tare coming from the POS and preset tare coming from the instrument and tare device of the instrument. Note: 2 to 5 above to be declared by the manufacturer. User Manual CAT 27 scales series ELZAB S.A.
  • Page 22: Configuration Of The Communication Parameters Of The Scale

    The factory settings allow the scale to cooperate with every cash FACTORY SETTINGS register produced by ELZAB SA factory which was approved by the Ministry of Finance since 2001. 6.1. Configuration of the communication parameters of the scale Configuration of the communication parameters is on choosing an appropriate protocol by using PROTOCOL TYPE function.
  • Page 23 0x2E Decimal 0x2E 0x30 .. 0x39 Digit 0 .. 9 0x30 0x30 .. 0x39 Digit 0 .. 9 0x34 0x30 .. 0x39 Digit 0 .. 9 (LSD) 0x35 0x0D 0x0D 0x0A 0x0A User Manual CAT 27 scales series ELZAB S.A.
  • Page 24 0x30 .. 0x39 Price 0 .. 9 0x35 0x30 .. 0x39 Price 0 .. 9 (LSD) 0x30 0x30 .. 0x39 Amount 0 .. 9 (MSD) 0x30 0x30 .. 0x39 Amount 0 .. 9 0x30 ELZAB S.A. User Manual CAT 27 scales series...
  • Page 25: Checking The Host Connection

    Price 0 .. 9 0x35 (‘5’) 0x30 .. 0x39 or 0x20 Price 0 .. 9 0x35 (‘5’) 0x30 .. 0x39 Price 0 .. 9 (LSD) 0x30 (‘0’) 0x0A .. 0x3A Scale No. 0x0A 0x0A 0x0A User Manual CAT 27 scales series ELZAB S.A.
  • Page 26: Transmitting The Name Of Weighted Article To The Scale

    When the scale is operating in the scales system the NW byte takes a form of: The scale No. in the scales system Byte No. 22 Scale No. 1 0x0A Scale No. 2 0x1A Scale No. 3 0x2A Scale No. 4 0x3A ELZAB S.A. User Manual CAT 27 scales series...
  • Page 27: Reading Of The Program Version

    Initiation of the FLASH memory after it was cleared up. E9:FLASH MEMORY INIT Report the fault for servicing. Initial zeroing range exceeded when turning on the scale. W1:INIT RANGE EX. Decrease the load of the platter while turning on the scale. User Manual CAT 27 scales series ELZAB S.A.
  • Page 28: Conformity Assessment (Verification)

    The user manual contains a declaration of conformity which confirms compliance with metrological and legal requirements. The declaration of conformity is also available on the company’s web site www.elzab.pl. Copy of the declaration of conformity may be required during the another periodic legal verification.
  • Page 29 In addition, on each scale there is a warranty sticker, the destruction of which causes the loss of the manufacturer’s warranty. The sticker is on the assembly screw of the main module of the scale. User Manual CAT 27 scales series ELZAB S.A.
  • Page 30 ELZAB S.A. User Manual CAT 27 scales series...
  • Page 31     This manual is dedicated to the following scale models: NEPTUN 2 (different versions) – code: WB4 ELZAB CAT 27 scale SATURN 2 (different versions) – code: WB1 ELZAB CAT 27 scale VEGA 2 (different versions) – code: WB5 and WB6...
  • Page 32 HEADQUARTERS: ELZAB 1 41 - 813 Zabrze Poland tel. +48 32 272 20 21 www.elzab.pl www.facebook.com/ElzabSA WB1IOA00...

Table of Contents