3.1.4 Troubleshooting Recommendations Display Mode

Having displayed information about single or multiple errors, the self-test may recommend the following
troubleshooting scenarios depending on how critical the errors are:
1. Block further operation of the scale and recommend switching it off (in Error Type column of Table 1 such
errors are marked with the tag "B" [blocked]);
2. Recommend entering the Service Menu, and if the operator fails to do so – block the scale and recommend
switching it off (in Error Type column of Table 1 such errors are marked with the tag "S/B" [Service Menu or
blocked]);
3. Recommend entering the System Menu, and if the operator fails to do so or if the system administrator does
not take recommended actions in the System Menu – go to Main Mode, but certain functions will not be
available (in Error Type column of Table 1 such errors are marked with the tag "M/R" [System Menu or
restrictions]);
4. Disable certain functions, display a warning about such restrictions (see
Mode (in Error Type column of Table 1 such errors are marked with the tag "R" [restrictions]);
5. Recommend setting date and time, and having done that – go to Main Mode (in Error Type column of Table 1
such errors are marked with the tag "DT" [set date and time]).
For an operator the first two scenarios require assistance from the system administrator. An operator may
continue work in Scenarios 3 (by refusing to enter the System Menu and pressing the key
allow that. In Scenario 5, an operator should simply enter current date and time, but if such errors occur on every
power-up of the scale, report it to the system administrator (refer to paragraphs 2.9.3 Date and 2.9.4 Time).

3.1.5 Power-Up Errors

Table 1
Message
No message
displayed
36
Error Type Description
No sound signals at power-up, the
—/B
display is off.
Illustration 30
below), and go to Main
Illustration 30
) and 4, if the restrictions
Troubleshooting
Make sure that the electrical
network is operating properly, the
power switch of the scale is on,
otherwise contact the system
administrator.
www.elzab.pl