Functions Remotely Controlled By System Administrator; Clear Db/Sales Records; Quick Db Update Mode - ELZAB Eco Print Operator's Manual

Table of Contents

Advertisement

ELZAB S.A.  +48 32 272 20 21

2.11 Functions Remotely Controlled by System Administrator

In Main Mode some of the functions can be remotely performed by the system administrator from the PC.
Scale operators are informed about these actions with messages displayed by the scale. Urgent message is a specially
designed function to instantly transmit a short message from the system administrator to the operator.

2.11.1 Clear DB/Sales Records

The system administrator can enable a mode to clear sales records and the internal memory of the scale
containing PLUs and messages (database). In Clear DB/Sales Records Mode the operation of the scale is blocked, and
the scale displays a message as in
Wait for the scale to return to normal operating mode. Remember that having deleted all PLU data and
messages, it will be impossible to call up items (refer to paragraph 2.1 Selecting Items) until new PLUs and messages
are loaded to the scale.

2.11.2 Quick DB Update Mode

The system administrator can enable the mode of fast loading of PLUs and messages to the internal memory
of the scale. In Quick DB Update Mode the operation of the scale is locked, and the scale displays a message as in
Illustration 24
below:
If it is not necessary to weigh or label products, when quick DB update is in progress, it is recommended to wait
for the update to complete, because it takes no longer than 1.5 minutes (time given for an update via Ethernet network
not overloaded with third-party traffic, if PLUs and messages are loaded in blocks). The scale will return to the normal
operating mode, when the loading is finished. If there is no opportunity to wait for the loading to complete, an operator
can quit Quick DB Update Mode by pressing the key
DB update will continue at the standard speed. Standard speed update takes longer time to update the DB, but loading
will not interfere with the operation of the scale.
Important!
It should be noted that when the DB is being updated, PLU data can change significantly, e.g. unit price,
shelf life, etc. can change. It may occur that a different item will be recorded to a certain PLU unit. Always contact the
32
Illustration 23
below:
. The scale will return to the normal operating mode, and the
www.elzab.pl
Illustration 23
Illustration 24

Advertisement

Table of Contents
loading

Table of Contents