11.9.8 Replace the suction valves.
Switch off the operating mode switch and secure it
against restart.
Shut off water supply.
Take the pressure off the high pressure system by
opening the gun. Check the pressure ratio of the high
pressure system on the pump manometer.
Remove the valve from the pump seat.
Components in the disassembled condition
1 Piston with tappet
2 Spring
3 Valve casing
4 Diaphragm
Open the lockscrews of the 3 suction valves and re-
place the O-rings.
English 5.906-736.0 Rev. 00 (07/15)
119