faults to prevent damage to the amplifier and speakers.
Remote standby port — Enables the NetPA AT to be remotely powered down when
not in use, reducing operating cost.
High pass filter for high impedance model — This switch selectable filter, available
on the 70 volt model, rolls off frequencies below 80 Hz to prevent saturation of speaker
transformers.
Front-mounted signal and protection indication LEDs — Provides convenient
indication of input signal presence and protection circuit activation.
Link LED indicator for Dante port — Provides visual indication of synchronization to
the master clock on the Dante network.
Highly reliable, energy efficient internal universal power supply
NetPA AT Series User Guide • Introduction