5.2.3 E3 – ELEVATION STALL ERROR
OVERVIEW
To reduce the risk of elevation motor/system damage or overheating in the event of a stall elevation stall conditions are
monitored. If movement is commanded and the position feedback indicates no movement-taking place an elevation stall
error is called. This problem has been caused most frequently by overheated elevation motor.
PROBLEM IDENTIFICATION
The movement can be directly controlled and the elevation position feedback can be directly read in the hardware test.
To observe the elevation error, enter the hardware screen (see HARDWARE TEST SCREEN section in this document). Use
the
"ELEVATION UP/DOWN"
mechanism). Observe the elevation position feedback displayed in the elevation window. Use the below guide to
identify the problem. ENSURE NO OBSTRUCTIONS (FURNITURE, OBJECTS, PEOPLE ETC.) IS PREVENTING
PROPER TREADMILL MOVEMENT BEFORE CHECKING FOR ERROR CAUSE.
E3 ERROR
ENTER HARDWARE TEST SCREEN
RUN ELEVATION UP AND DOWN
TREADMILL
MOVES UP
OR DOWN?
FEEDBACK
CHANGES
W/ ELEVATION
POSITION FEEDBACK PROBLEM
Date of last revision: 11.06
keys to directly control the elevation movement (within the travel limits of the elevation
N
OVERHEATED?
Y
MOTOR MOVEMENT ISSUE
Y
CALIBRATE ELEVATION
N
Y
MOTOR
ELEVATION MOTOR
OVERHEATING ISSUE
N
30
TREADMILL.UPPERBDENG.DGF1J.CVTM0033.CVTM0031.REV2