Set Magnet Count; Set Effective Diameter - Vision Fitness T9800S Engineering Manual

Hide thumbs Also See for T9800S:
Table of Contents

Advertisement

DGF1J Upper Board: Engineering Guide

4.5 SET MAGNET COUNT

Magnet count adjustment allows the same console software to be used with different magnet counts at different loca-
tions (2 pulses per revolution of the belt roller – Reliance Drive Configuration, 44 pulses per roller revolution –AC motor
controller)
1. Press the
"ELEVATION UP/DOWN"
2. Press the
"ENTER"
3. Select the correct magnet count for the current motor (44 for the AC Motor Controller).
4. Press the
"ENTER"

4.6 SET EFFECTIVE DIAMETER

Allows for adjustment for belt/roller diameter variations and compensates for pulley ratio's when using the AC motor
controller (AC motor controller measures pulses at the motor shaft).
1. Press the
"ELEVATION UP/DOWN"
2. Press the
"ENTER"
3. CAUTION!!! THE BELT WILL START AND RAMP UP APPROXIMATELY 12 MPH IN THIS STEP!!!
Allow the motor speed to stabilized and then measure the belt speed. Using the
adjust the effective diameter value (displayed in the elevation window) until the displayed speed (speed win-
dow) matches the measured speed +/- .05 MPH. THE MAGNET COUNT PARAMETER MUST BE
PROPERLY SET BEFORE ADJUSTING THIS VALUE!!!
4. Press the
"ENTER"
4.7 RUN AUTO-CALIBRATION
Automatically detects and stores the correct values for PWM START, MINIMUM, HALF AND MAXIMUM variables and
the maximum and minimum elevation values. Failure of the auto-calibration routine is indicted with a triple beep and
the failure cause will be temporarily displayed in the alphanumeric display.
1. Press the
"ELEVATION UP/DOWN"
2. Press the
"ENTER"
OCCUR UNDER SOFTWARE CONTROL!!!
3. Allow the auto-calibration routine to function. Current operations are indicated in the alphanumeric display.
4. Auto-calibration routines will indicate successful completion with a double beep or failure with a triple beep.
PWM START
Is the PWM minimum threshold in which belt movement occurs. This parameter is used to ensure belt movement occurs
within 2 seconds from the end of the "3" count but not before.
1. Press the
"ELEVATION UP/DOWN"
2. Press the
"ENTER"
OCCUR WHEN THE PWM OUTPUT VALUE EXCEEDS THE MOTOR STARTING THRESHOLD!!!
3. SLOWLY increase the PWM value using the
(approximately 0.3 MPH should be displayed in the speed window).
4. Press the
"ENTER"
Date of last revision: 11.06
keys until " " P P 1 1 9 9 M M A A G G N N E E T T C C O O U U N N T T " " is displayed in the alphanumeric display.
key, the magnet count displayed in the time window will flash.
key to save or the
"STOP"
keys until " " P P 2 2 0 0 E E F F F F D D I I A A M M E E T T E E R R " " is displayed in the alphanumeric display.
key.
key to save or the
"STOP"
keys until " " A A U U T T O O - - C C A A L L I I B B R R A A T T I I O O N N " " is displayed in the alphanumeric display.
key. CAUTION!!! BELT MOTOR WILL BE ENABLED AND MOVEMENT WILL
keys until " " P P 2 2 1 1 P P W W M M S S T T A A R R T T S S P P D D " " is displayed in the alphanumeric display.
key. CAUTION!!! BELT MOTOR WILL BE ENABLED AND MOVEMENT WILL
"SPEED UP/DOWN"
key to save or the
"STOP"
key to retain the previous value.
key to retain the previous value.
keys until the belt begins moving
key to retain the previous value.
24
TREADMILL.UPPERBDENG.DGF1J.CVTM0033.CVTM0031.REV2
keys,
"SPEED UP/DOWN"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T9800hrt

Table of Contents