Run Auto-Calibration; E9 - Speed Range Error - Vision Fitness T9800S Engineering Manual

Hide thumbs Also See for T9800S:
Table of Contents

Advertisement

DGF1J Upper Board: Engineering Guide
5.3.4 E9 – SPEED RANGE ERROR
OVERVIEW
During normal run time operation the value stored during auto calibration is used to initially set the speed (e.g. target
speed = 12 MPH, PWM ticks = Maximum PWM = 363). Once the speed stabilized the actual speed is monitored
and if different than the target speed the PWM value is adjusted until the actual speed matches the target speed. If
the PWM value is changed by more than the amount of ticks required to change .8 MPH and the actual speed does
not match the target speed then an E9 error is flagged. This error indicates the motor controller system is unable to
maintain the target speed.
PROBLEM IDENTIFICATION
E9 ERROR
Before cycling power inspect the motor
controller for error (blinking red status
LED – SP600, 'E' code MD65,
LED 5 blinking –ACMC)
MOTOR
CONTROLLER ERROR
N
Start PWM half test and allow 20
seconds for belt to start moving
Measure speed and compare to value
displayed in time window
N
OK
Y

RUN AUTO-CALIBRATION

N
ERROR
GONE
Y
DONE
Date of last revision: 11.06
Record the error
Y
code from the
motor controller
(if possible)
Perform steps outlined in
speed feedback issue section
Perform steps outlined in
speed control issue section
36
Check for free
CYCLE
movement of
belt roller
POWER
movement
TREADMILL.UPPERBDENG.DGF1J.CVTM0033.CVTM0031.REV2