14 Technical data
(1)
Main power connection
Only for normal power supply (standard)
A1P
X1A:3
1
X19A:1
3
5
X1M
L1 L2 L3
N
X6Y
X6YA
X6YB
X2M
30 31
Switch box
Q1DI
3N~, 50 Hz
L1 L2 L3 N
400 V AC
Only for preferential kWh rate power supply
Use normal kWh rate power supply for hydro PCB
A1P
X1A:3
1
X19A:1
3
5
X1M
L1 L2 L3
N
X6Y
X6YA
X6YB
X2M
30 31
Switch box
Q1DI
L1 L2 L3 N
1N~, 50 Hz
Preferential
Q2DI
230 V AC; 6,3 A
3N~, 50 Hz
kWh rate
400 V AC
Normal kWh rate
power supply
power supply
contact:
L
N
16 V DC detection
(voltage supplied
by PCB)
(6)
Field supplied options
3
X2M
34
35
X2M
5
6 7
DHW pump
M
output
230 V AC
1~
M2S
M2P
Max. load:
supplied
2 A (inrush) -
by PCB
230 V AC
DHW pump
1A (continuous)
Normally open
X5M
3
7 8 9
10
X2M
5
6 7
5 V DC
M2S
pulse
230 V AC
detection
supplied
(voltage
by PCB
supplied by
PCB)
Normally closed
Shut-off valve
Electrical meters
Installer reference guide
76
(2)
Outdoor ambient
(4)
User interface
sensor
1
X5M
1 2
X5M
X5M
3 4
11 12
Switch box
Switch box
1
2
R1T
A2P
-t°
P1P2
(3)
Option external
User
interface
1
indoor ambient sensor
X5M
3 4
X5M
5 6
Switch
box
1
2
R6T
-t°
(7)
External room thermostats and heat pump convector
Main LWT zone
1 2
3
4
X2M
5
1
2
3
H C
H C
A3P
H C
C
H
COM
COM
Switch box
R1T
-t°
only for wired
only for wireless
thermostat
thermostat
Additional LWT zone
3 4
X2M
6
3 4
1a 2a
1a 2a
H
C
H
C
Switch box
A3P
C
H
H C
COM
COM
R1T
-t°
only for wired
only for wireless thermostat
thermostat
(5) Option PCBs
X33A:1 2 3 4 5 6
CN2:1 2 3 4 5 6
CN1:1
3
F2U
A2P
P1P2
KCR
KHR
X1 X2
YC
Y1
Only for
Remote user
interface option
X2M
21
28
L N
29
Ext. heat
source (*)
Options: boiler output, alarm output, On/OFF output
Only for digital I/O PCB option
4
X2M
only for
external sensor
(floor/ambient)
A4P
A3P
X1M
L N
R2T
R1H
PC
R1T
-t°
%H20
-t°
X2M
only for
external sensor
(floor/ ambient)
A3P
A4P
X1M
L N
R2T
R1H
PC
R1T
-t°
%H20
-t°
X85A:1 2 3 4 5 6
A8P
A4P
SS1
ON
X80A:1 2 3 4 5 6 7 8 9 10 11 12
OFF
F1U
X801M
1 2
3 4 5
KHUR
Y2
Power limitation
Space heating
digital inputs:
Alarm
On/OFF
output (*)
12 V DC / 12 mA
output (*)
detection (voltage
supplied by PCB)
(*) Max. load:
Only for demand PCB option
0.3 A - 250 V AC
Min. load:
20 mA - 5 V DC
(8)
Option for brine pressure switch
connection kit
7
X18A:1 2 3 4
5
1
4
X2M
5
A3P
5 6
X11M
S1L
7
X18A:1 2 3 4
only for heat
pump convector
6
4
X2M
6
1a
A3P
5 6
X11M
1 2 3 4
-X1Y
S1L
only for heat
pump convector
Only for brine pressure switch connection kit
4P355433-1A_page 4
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351748-1D – 2016.02
A1P
DS1
ON
OFF
1 2 3 4
Switch box
A9P
Switch box
A9P
Switch box
X7M
1
2
S1P P<
5 V DC / 0,05 mA
detection (voltage
supplied by PCB)