Error Codes: Overview - Daikin EGSQH10S18AA9W Installer's Reference Manual

Altherma ground source heat pump
Hide thumbs Also See for EGSQH10S18AA9W:
Table of Contents

Advertisement

12 Troubleshooting
12.4.1

Error codes: Overview

Error codes of the unit
Error code
Detailed error
code
E1
00
E3
00
E5
00
E7
62
E9
00
H0
01
H3
00
H9
00
F3
00
J1
00
JA
00
J3
00
J6
00
J7
12
J8
07
L3
00
Installer reference guide
64
Description
OU: PCB defect.
Power reset required.
Please contact your dealer.
OU: Actuation of high pressure
switch (HPS).
Please contact your dealer.
OU: Overheat of inverter
compressor motor.
Please contact your dealer.
Brine flow Abnormality
Please contact your dealer.
Expansion valve abnormality.
Please contact your dealer.
Brine flow switch malfunction
Please contact your dealer.
OU: Malfunction of high
pressure switch (HPS)
Please contact your dealer.
OU: Malfunction of outdoor
air thermistor.
Please contact your dealer.
OU: Malfunction of discharge
pipe temperature.
Please contact your dealer.
High pressure sensor
abnormality.
Please contact your dealer.
OU: Malfunction of high
pressure sensor.
Please contact your dealer.
OU: Malfunction of discharge
pipe thermistor.
Please contact your dealer.
OU: Malfunction of heat
exchanger thermistor.
Please contact your dealer.
Brine inlet thermistor
abnormality
Please contact your dealer.
Brine outlet thermistor
abnormality
Please contact your dealer.
OU: Electrical box temperature
rise problem.
Please contact your dealer.
Error code
Detailed error
code
L4
00
L5
00
P4
00
U0
02
U2
00
U4
00
A1
00
AA
01
UA
00
7H
01
89
01
8H
00
8F
00
C0
00
U3
00
81
00
Daikin Altherma ground source heat pump
Description
OU: Malfunction of inverter
radiating fin temperature rise.
Please contact your dealer.
OU: Inverter instantaneous
overcurrent (DC).
Please contact your dealer.
OU: Malfunction of radiating
fin temperature sensor.
Please contact your dealer.
Refrigerant shortage
Please contact your dealer.
OU: Defect of power supply
voltage.
Please contact your dealer.
Indoor/outdoor unit
communication problem.
Zero cross detection problem.
Power reset required.
Please contact your dealer.
Backup heater overheated.
Power reset required.
Please contact your dealer.
Indoor unit, outdoor unit
matching problem.
Power reset required.
Water flow problem.
Heat exchanger frozen.
Abnormal increase outlet
water temperature.
Abnormal increase outlet
water temperature (DHW).
Flow sensor/switch malfunction.
Please contact your dealer.
Under floor heating screed
dryout function not completed
correctly.
Leaving water temperature
sensor problem.
Please contact your dealer.
EGSQH10S18AA9W
4P351748-1D – 2016.02

Advertisement

Table of Contents
loading

Table of Contents