Summary of Contents for Daikin EGSQH10S18AA9W

  • Page 1 Operation manual Daikin Altherma ground source heat pump Operation manual English Daikin Altherma ground source heat pump EGSQH10S18AA9W...
  • Page 2: Table Of Contents

    Check  if  he  has  filled  in  the  installer settings tables. If not, request him to do so. ▪ Keep the documentation for future reference. Target audience End users Documentation set This  document  is  part  of  a  documentation  set.  The  complete  set consists of: Main zone. Example: Living room. Additional zone. Example: Bedroom. Technical room. Example: Garage. Brine loop Indoor unit heat pump Domestic hot water (DHW) tank User interface at the indoor unit Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 3: Operation

    At the next scheduled action, the desired temperature will decrease. The preset value (Comfort or Eco) or scheduled value is temporarily overruled.  HOME PAGES ▪ Switches between home pages (when you are on a home The system will produce domestic hot water for the page). indicated number of persons. ▪ Goes to the default home page (when you are in the menu The DHW tank booster mode is active or ready to be structure). activated.  MALFUNCTION INFORMATION Quiet mode is active. If a malfunction occurs,   is displayed on the home pages. Press   to display more information about the malfunction. Holiday mode is active or ready to be activated.  ON/OFF Child lock mode and/or function lock mode is active. Turns  ON  or  OFF  one  of  the  controls  (room  temperature, leaving water temperature, DHW tank temperature). EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 4: Space Heating Control

    Result:  You  can  read  out  the  desired  temperature.  Example:  22.0°C Desired temperature 60°C To temporarily overrule the room temperature schedule 50°C 1 Go to the room temperature home page (Room). 40°C 2 Use   or   to adjust the temperature. To change the mode from scheduled to preset value 15°C Prerequisite: User profile = Detailed. 1 Go to the room temperature home page (Room). 00:00 07:00 14:00 21:00 DHW tank temperature 2 Press   or   to select a preset value (  or  ). Time Result: The mode will return to Scheduled according to the overrule period. Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 5: Scheduled + Reheat Mode

    To read out and overrule the active or next scheduled desired temperature (in scheduled mode or scheduled + reheat mode) To select which schedule you currently want to use 1 Go to the DHW tank temperature home page (Tank). 1 Go to [5]:   > Select schedules. 60°C 2 Select for which control you want to use a schedule. Example: Result:   or   is displayed. [5.1] Room temperature. 2 Press   or   to overrule. Note: If the desired temperature is 3 Select  for  which  operation  mode  you  want  to  use  a  schedule. weather dependent, you cannot change it on the home page. Example: [5.1.1] Heating. 4 Select a predefined or user­defined schedule and press  EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 6: Menu Structure: Overview User Settings

    Backlit LCD time Allowed operation mode User profile Unit of measurement Available home pages [7.3] Set schedules Room temp. LWT main LWT additional Tank temp. Quiet mode DHW pump [7.4] Preset values Room temperature LWT main Tank temperature Quiet level Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 7 ▪ For  shorter  periods:  You  can  overrule  the  scheduled  room temperature.  Example:  When  you  have  a  party,  or  when  you are leaving for a couple of hours. ▪ For  longer  periods:  You  can  use  the  holiday  mode.  Example: When  you  stay  at  home  during  your  holiday,  or  when  you  go away during your holiday. EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 8: Troubleshooting

    Periodical  inspections  for  refrigerant  leaks  may  be  required ▪ Adjust  the  DHW  tank depending on the applicable legislation. Please contact your installer temperature  schedule. for more information. Example:  Program  additionally  heat  up  To find the contact/helpdesk DHW  tank  to  a  preset  value (Storage  eco  =  lower  tank number temperature) during the day. Go to [6.3.2]:   > Information > Error handling > Contact/helpdesk number. Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 9 ▪ Call  your  local  dealer  to  get the heat pump fixed. INFORMATION When  the  backup  heater  takes  over  the  heat  load, electricity consumption will be considerably higher. Glossary DHW = Domestic hot water Hot  water  used,  in  any  type  of  building,  for  domestic purposes. LWT = Leaving water temperature Water temperature at the water outlet of the heat pump. EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1C – 2014.03...
  • Page 12 4P351750-1 C 0000000- 4P351750­1C  2014.03...