Operation manual
Daikin Altherma ground source heat pump
Operation manual
English
Daikin Altherma ground source heat pump
EGSQH10S18AA9W

Advertisement

Table of Contents
loading

Summary of Contents for Daikin EGSQH10S18AA9W

  • Page 1 Operation manual Daikin Altherma ground source heat pump Operation manual English Daikin Altherma ground source heat pump EGSQH10S18AA9W...
  • Page 2: About This Document

    Check  if  he  has  filled  in  the  installer settings tables. If not, request him to do so. ▪ Keep the documentation for future reference. Target audience End users Documentation set This  document  is  part  of  a  documentation  set.  The  complete  set Main zone. Example: Living room. consists of: Additional zone. Example: Bedroom. Technical room. Example: Garage. Brine loop Indoor unit heat pump Domestic hot water (DHW) tank User interface at the indoor unit User interface in the living room, used as room thermostat Underfloor heating Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 3: Overview: Operation

    ▪ Goes to the default home page (when you are in the menu The DHW tank booster mode is active or ready to be structure). activated.  MALFUNCTION INFORMATION Quiet mode is active. If  a  malfunction  occurs,    is  displayed  on  the  home  pages. Press   to display more information about the malfunction. Holiday mode is active or ready to be activated.  ON/OFF Child lock mode and/or function lock mode is active. Turns  ON  or  OFF  one  of  the  controls  (room  temperature, leaving water temperature, DHW tank temperature). EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 4: Space Heating Control

     or   to adjust the temperature. 50°C 40°C To change the mode from scheduled to preset value Prerequisite: User profile = Detailed. 15°C 1 Go to the room temperature home page (Room). 2 Press   or   to select a preset value (  or  ). 00:00 07:00 14:00 21:00 Result: The mode will return to Scheduled according to the overrule period. ▪ T : DHW tank temperature To set the overrule period ▪ t: Time 1 Go to [7.2]:   > User settings > Temperature lock. 2 Select a value and press  ▪ Permanent ▪ hours (2, 4, 6, 8) Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 5: Schedules: Example

    To read out and overrule the active or next scheduled desired To select which schedule you currently want to use temperature (in scheduled mode or scheduled + reheat mode) 1 Go to [5]:   > Select schedules. 1 Go to the DHW tank temperature home page (Tank). 2 Select for which control you want to use a schedule. Example: [5.1] Room temperature. Result:   or   is displayed. 3 Select  for  which  operation  mode  you  want  to  use  a  schedule. 2 Press   or   to overrule. Note: If the desired temperature is Example: [5.1.1] Heating. weather dependent, you cannot change it on the home page. 4 Select a predefined or user­defined schedule and press  EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 6: Menu Structure: Overview

    Quiet mode DHW pump [7.4] Preset values Room temperature LWT main Tank temperature Quiet level INFORMATION Energy  metering  functionality  is  NOT  applicable  and/or NOT  valid  for  this  unit  if  it  is  calculated  by  the  unit.  If optional external meters are used, energy metering display is valid. Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 7: Installer Settings: Tables To Be Filled In By Installer

    ▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high. Example: After installation, lower the DHW tank temperature daily Leaving water temperature: Additional zone [A.3.1.2] by 1°C and check if you still have enough hot water. LWT setpoint mode 0 (Fixed) ▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during Set weather­dependent heating 25/40/15/−10 periods of the day when instant hot water is necessary. Example: Leaving water temperature: Delta T emitter [A.3.1.3] In the morning and evening. Heating 5°C Leaving water temperature: Modulation [A.3.1.1.5] Modulated LWT 0 (No) Leaving water temperature: Emitter type [A.3.1.1.7] Emitter type 1 (Slow) EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 8: Maintenance And Service

    Hot  water  used,  in  any  type  of  building,  for  domestic purposes. Symptom: You are feeling too cold LWT = Leaving water temperature (hot) in your living room Water temperature at the water outlet of the heat pump. Possible cause Corrective action The desired room temperature is Increase (decrease) the desired too low (high). room temperature. If the problem recurs daily, do one of the following: ▪ Increase  (decrease)  the  room temperature preset value. ▪ Adjust  the  room  temperature schedule. The desired room temperature Increase the desired leaving cannot be reached. water temperature in accordance with the heat emitter type. Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351750­1 – 2013.06...
  • Page 12 4P351750-1 0000000J 4P351750­1  2013.06...