Field settings table
Breadcrumb
Field code
Setting name
A.8
[3-00]
Is auto restart of the unit allowed?
A.8
[3-01]
--
A.8
[3-02]
--
A.8
[3-03]
--
A.8
[3-04]
--
A.8
[3-05]
--
A.8
[3-06]
What is the maximum desired room temperature in heating?
A.8
[3-07]
What is the mimimum desired room temperature in heating?
A.8
[3-08]
--
A.8
[3-09]
--
A.8
[4-00]
What is the BUH operation mode?
A.8
[4-01]
--
A.8
[4-02]
Below which outdoor temperature is heating allowed?
A.8
[4-03]
--
A.8
[4-04]
--
A.8
[4-05]
--
A.8
[4-06]
-- (Do not change this value)
A.8
[4-07]
Enable the second step of the backup heater?
A.8
[4-08]
Which power limitation mode is required on the system?
A.8
[4-09]
Which power limitation type is required?
A.8
[4-0A]
--
A.8
[4-0B]
--
A.8
[4-0D]
--
A.8
[5-00]
Is backup heater or boiler operation allowed above equilibrium
temperature during space heating operation?
A.8
[5-01]
What is the equilibrium temperature for the building?
A.8
[5-02]
--
A.8
[5-03]
--
A.8
[5-04]
--
A.8
[5-05]
What is the requested limit for DI1?
A.8
[5-06]
What is the requested limit for DI2?
A.8
[5-07]
What is the requested limit for DI3?
A.8
[5-08]
What is the requested limit for DI4?
A.8
[5-09]
What is the requested limit for DI1?
A.8
[5-0A]
What is the requested limit for DI2?
A.8
[5-0B]
What is the requested limit for DI3?
A.8
[5-0C]
What is the requested limit for DI4?
A.8
[5-0D]
What type of backup heater installation is used?
A.8
[5-0E]
--
A.8
[6-00]
The temperature difference determining the heat pump ON temperature.
A.8
[6-01]
The temperature difference determining the heat pump OFF temperature.
--
A.8
[6-02]
A.8
[6-03]
What is the capacity of the backup heater step 1?
A.8
[6-04]
What is the capacity of the backup heater step 2?
A.8
[6-05]
--
A.8
[6-06]
--
A.8
[6-07]
--
A.8
[6-08]
What is the hysteresis to be used in reheat mode?
A.8
[6-09]
--
A.8
[6-0A]
What is the desired comfort storage temperature?
A.8
[6-0B]
What is the desired eco storage temperature?
A.8
[6-0C]
What is the desired reheat temperature?
A.8
[6-0D]
What is the desired DHW production type?
A.8
[6-0E]
What is the maximum temperature setpoint?
A.8
[7-00]
--
A.8
[7-01]
--
A.8
[7-02]
How many leaving water temperature zones are there?
A.8
[7-03]
PE factor
A.8
[7-04]
--
A.8
[7-05]
--
A.8
[8-00]
--
A.8
[8-01]
Maximum running time for domestic hot water operation.
A.8
[8-02]
Anti-recycling time.
A.8
[8-03]
--
A.8
[8-04]
Additional running time for the maximum running time.
A.8
[8-05]
Allow modulation of the LWT to control the room temp?
A.8
[8-06]
Leaving water temperature maximum modulation.
A.8
[8-07]
--
(#) Setting is not applicable for this unit. Do not change the default value.
(##) Setting is not applicable for this unit.
*GSQH10S18AA9W / ThermaliaC12*
Range, step
Default value
R/W
0: No
1: Yes
0
1
4
2
1
R/W
18~30°C, step: A.3.2.4
30°C
R/W
12~18°C, step: A.3.2.4
12°C
35
15
R/W
0: Disabled
1: Enabled
2: Only DHW
0
R/W
14~35°C, step: 1°C
35°C
3
2
0
0/1
R/W
0: No
1: Yes
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
0
1
3
R/W
0: Allowed
1: Not allowed
R/W
-15~35°C, step: 1°C
0°C
0
0
10
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/O
4: 3PN,(1/2)
1
R/W
2~20°C, step: 1°C
2°C
R/W
0~10°C, step: 1°C
2°C
0
R/W
0~10 kW, step: 0,2 kW
3 kW
R/W
0~10 kW, step: 0,2kW
3 kW
0
0
0
R/W
2~20°C, step: 1°C
10°C
0
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
40~60°C, step: 1°C
60°C
0
2
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0~6, step: 0,1
2,5
0
0
1
R/W
5~95 min, step: 5 min
30 min
R/W
0~10 hour, step: 0,5 hour
0,5 hour
50
R/W
0~95 min, step: 5 min
95 min
R/W
0: No
1: Yes
R/W
0~10°C, step: 1°C
3°C
18
5/7
Installer setting at variance with
default value
Date
Value
4P359382-1D - 2015.02