3.7.4 Set Timeout Time

Scroll to the "Timeout Time" menu item and press "#" to enter its interface.
For setting the minutes, input three digits in the range of 0-999, and for setting seconds,
input two digits in the range of 0-59. Press "#" to confirm and the setting will take effect.
Press "*" to exit and the setting will not take effect.

3.7.5 Set Direction

Scroll to the "Direction" menu item and press "#" to enter its interface.
The screen will display the status of the direction. Press "#" to toggle between Entry and
Exit status. Press "*" to exit and the setting will take effect.

3.8 Alarm Setting

The EBC980 controller provides 1 fire alarm input, 1 alarm input and 1 alarm output. Users
can carry out detailed configurations through the user interface. Details will be introduced
below.

3.8.1 Composition of Alarm

The alarm input of the EBC980 controller can be connected with external alarm equipment
such as a PIR sensor, glass breakage sensor, etc and the alarm output can drive a 4A alarm
relay.
Timeout Time
000 Min 03 Sec
Cancel
Direction
Entry
[#]to toggle
OK
Direction
[#]to toggle
34
Exit