Set Over Time; Door Access Mode - EverFocus EBC980R User Manual

D/mifare finger vein single-door controller
Table of Contents

Advertisement

3.7.2 Set Over Time

The door status switch is used to detect the open/closed status of the door. In general cases,
the door is closed. In case of door opening, the door should be closed after being opened
for a period of time, during which the controller may not receive the signal from the door
status switch. At the end of the door open time, if a door which should be closed is not
closed, timing will start and the recorded time is the Door Over Time. When the time has
exceeded, the controller will generate an alarm. The default Door Over Time is 10s.The
maximum Door Over Time set on the controller is 999 min 59s.
Scroll to "Set Over Time" menu item and press "#" to enter its interface.
For setting "minutes," input three digits in the range of 0-999 and for setting "seconds,"
input two digits in the range of 0-59. Press "#" to confirm and the setting will take effect.
Press "*" to exit and the setting will not take effect.

3.7.3 Door Access Mode

Press "#" to enter the submenu. Select the desired mode and press the numerical key "5" to
select. The selected item is marked with a "*". Then, press"*" or"#" to exit the current
interface.
Door Over Time
000 Min 10 Sec
Cancel
Follow schedule
Finger Only
Finger + PIN
Finger or PIN
OK
Normal Close
Always Unlocked
33