8.6.5. View Installed I/O cards' hardware

Description: Shows the hardware name and revision of the installed cards.
Info: This router model is a compact type, so there are no separate input / output cards. Separate
card slot descriptors are listed only because of compatibility issues.
Command {IS}
Response (SL#●0● <MB_DESC>)CrLf
Explanation (MX16x16DVI-Plus router): The router reports as if it has two output ad two
input cards.

8.6.6. View installed controllers' firmware

Description: Shows the firmware revisions of the installed controllers.
Command {FC}
Response (<CARD_FIRMWARE>)CrLf ←

8.6.7. View current control protocol

Description: Shows the RS-232, TCP/IP control protocol.
Command {P_?}
Response CURRENT●PROTOCOL●
Legend: <x> stands for the active protocol.
Explanation: Protocol 1 is active here.
Section 8. Programmers reference
Format
(SL#●1●<OB_DESC>)CrLf
(SL#●2●<OB_DESC>)CrLf
(SL#●3●<OB_DESC>)CrLf
(SL#●4●<OB_DESC>)CrLf
(SL#●5●<IB_DESC>)CrLf
(SL#●6●<IB_DESC>)CrLf
(SL#●7●<IB_DESC>)CrLf
(SL#●8●<IB_DESC>)CrLf
Format
Format
=●#<x>)CrLf
Standalone MX DVI-Plus family
Example (MX16x16DVI-Plus)
→ {is}
(SL# 0 MX16X16DVI-PLUS SCH_2.5
PCB_2.5)CrLf
(SL# 1 MX16x16DVI-PLUS-OB
SCH_2.5 PCB_2.5)CrLf
(SL# 2 MX16x16DVI-PLUS-OB
SCH_2.5 PCB_2.5)CrLf
(SL# 3 Empty Slot)CrLf
(SL# 4 Empty Slot)CrLf
(SL# 5 MX16x16DVI-PLUS-IB
SCH_2.5 PCB_2.5)CrLf
(SL# 6 MX16x16DVI-PLUS-IB
SCH_2.5 PCB_2.5)CrLf
(SL# 7 Empty Slot)CrLf
(SL# 4 Empty Slot)CrLf
Example
→ {fc}
(CF MX-CP FW:1.0.8 @ 0x10)CrLf
(CF MX-DVI-EDID FW:3.2.3 @
0x50)CrLf
Example
→ {p_?}
(CURRENT PROTOCOL = #1)CrLf