Using the VISCA RS-422 connector
pin assignments
The VISCA RS-422 connector pin
assignments
1
8
Pin No.
Function
1
TX –
2
TX +
3
RX –
4
GND
5
GND
6
RX +
7
8
Connection diagram of a Remote Control
unit (RM-IP10)
1
9
RM-IP10
1
2
3
Shield
4
5
GND
6
RX –
7
RX +
8
TX –
9
TX +
Notes
• In order to stabilize the voltage level of the signal,
connect both ends to GND.
• For the network cable, use a cable that is category 5e or
higher and is equivalent or higher than a shield twist
pair.
1
8
SRG-360SHE
1
TX –
2
TX +
3
RX –
4
GND
5
GND
6
RX +
7
8