5-14. Memory (Program Storage Locations 1-4) (DX And LX Models If Available)

1
1st
2
3rd
2nd
Memory Locations
1−4
Each memory location (1 thru 4) can store parameters for both
polarities, and each polarity can store parameters for both pro-
cess (TIG or Stick) for a total of 16 programs.
.
Some features shown are
3
not available on all models.
AC
And
DC
TIG (HF or Lift)
And
Stick
TIG (HF or Lift)
And
Stick
1
Memory (Program Storage
1-4) Switch Pad
2
Polarity Switch Pad
3
Process Switch Pad
To create, change, or recall a
welding parameters program,
proceed as follows:
First, press Memory switch pad until
the desired program storage loca-
tion (1-4) LED is illuminated
Second, press Polarity switch pad
until the desired polarity, AC or DC,
LED is illuminated
Third, press Process switch pad un-
til desired process, TIG HF Impulse,
TIG Lift Arc, or Stick, LED is illumi-
nated.
The program at the chosen location,
for the desired polarity and process,
is now the active program.
Fourth, change or set all desired pa-
rameters (see Section 5-1 for pa-
rameters).
OM-2240 Page 31