F. 4T Momentary Operation (DX, LX And All CE Models)
SEL
Current (A)
Initial Slope
Initial Amps
Preflow
P&R
P&R = Push and release trigger.
* = Push and releasing during final slope will break the arc and go to postflow.
NOTE: For first torch trigger push & release, if trigger is held more than 3 seconds, trigger cycle ends
OM-2240 Page 44
1
H4E
P&R
=
4T Momentary Main
Main Amps
P&R
1
4T Momentary Meter
Display
Select 4T Momentary according
to Section 6-2C.
4T Momentary torch trigger op-
eration is as shown.
NOTE: When a remote switch is
connected to the welding power
source, use the remote switch to
control the weld cycle. Amper-
age is controlled by the welding
power source.
Application:
Use 4T Momentary trigger meth-
od when the functions of a re-
mote current control are desired,
but only a remote on/off control is
available.
Final Slope
Final Amps
*
Postflow
P&R
P&R

Hide quick links: