B. DC - GTAW 16 Gauge Stainless Steel Set-Up
This symbol indicates which functions should be active for stainless steel.
• Turn power on (switch located on rear panel)
Press Polarity switch pad until DC LED is lit
Press Process switch pad until TIG HF Impulse LED is lit
Press Output switch pad until RMT STD LED is lit
Press Adjust switch pad until Post Flow LED is lit
Turn Encoder control to set 8 seconds of Post Flow time
Press Amperage A switch pad until LED is lit
Turn Encoder control to set desired amperage (50 - 80 amps).
.
The ammeter displays the parameter for any of the following units of measure when they are active:
amperage, time, percentage, or frequency. The corresponding LED, located directly below the am-
meter, will also light up. The ammeter also displays actual amperage while welding.
Om-2240 Page 62
Ammeter
Encoder
207 694-A