E. Mini Logic Operation (DX, LX And All CE Models)
SEL
Initial Slope
Initial Amps
Preflow
P&H
R
P&H = Push and hold trigger
R = Release trigger
P&R = Push trigger and release in less than 3/4 seconds
* = Arc can be extinguished at final slope rate at any time by pushing and holding trigger.
1
H4L
Torch Trigger Operation
*
*
P&R
P&R
P&R
=
Mini Logic
Main Amps
*
P&R
1
Mini Logic Meter Display
Select Mini Logic according to Sec-
tion 6-2C.
Torch trigger operation is as shown.
While in mini logic, the operator
may use the trigger on the remote
device to toggle between initial
slope or main amps and initial amps
as illustrated.
During Mini Logic, Final Amperage
is not available. Final slope will al-
ways slope to minimum amperage
and end the cycle.
NOTE: When a remote switch is
connected to the welding power
source, use the remote switch to
control the weld cycle. Amperage is
controlled by the welding power
source.
Application: This ability to change
current levels without either initial
slope or final slope, gives the oper-
ator the opportunity to adjust filler
metal without breaking the arc.
Final Slope
*
P&R
P&H