5-16. Factory Parameter Defaults And Range And Resolution

Parameter
POLARITY
PROCESS
* Stick OCV
OUTPUT
*RMT 2T
A MAIN / PEAK
AC TIG
AC STICK
DC TIG
DC STICK
Spot Time
PULSER
PPS
PEAK t
BKGND A
SEQUENCER
INITIAL A
INITIAL SLOPE t
FINAL SLOPE t
FINAL A
ADJUST
PREFLOW
POST FLOW
DIG
AC WAVESHAPE
BALANCE
FREQUENCY
Default
DC
TIG HF Impulse
Low OCV
RMT STD
2T
RMT 2T can be reconfigured for: 2T / 4T / Mini Logic
/ 4T Momentary / Spot (see Section 6-2C)
150 A
110 A
150 A
110 A
1.0 S
Off
100 Hz
40%
25%
20 A
0 S
0 S
5 A
0.2 S
10.0 S
0.0 − 50.0 Seconds @ 0.2 Second Resolution
30%
75%
120 Hz
Range And Resolution
AC / DC
TIG HF Impulse / TIG Lift / Stick
Low OCV / Normal OCV
RMT STD / RMT 2T / ON
5 − 200 Amps
5 − 200 Amps
1 − 200 Amps
1 − 200 Amps
0.1 − 25.0 Seconds
ON / OFF
Dual Range And Resolution
0.1 − 9.9 / 10 − 500 Hertz
5 − 95 Percent
5 − 95 Percent
5 − 200 Amps AC
1 − 200 Amps DC
0.0 − 25.0 Seconds
0.0 − 25.0 Seconds
5 − 200 Amps AC
1 − 200 Amps DC
0.0 − 25.0 Seconds
0 − 100 Percent
30 − 99 Percent
20 − 250 Hertz
OM-2240 Page 33