Output Control And Trigger Functions For Dx Models - Miller Dynasty 210 Owner's Manual

Hide thumbs Also See for Dynasty 210:
Table of Contents

Advertisement

11-4. Output Control And Trigger Functions For DX Models

A. Remote (Standard), 2T, And 4TE Torch Trigger Operation
Current (A)
Initial Amps
Preflow
Time
Standard
P/H
P/H = Push and hold trigger
R = Release trigger
.
When a foot or finger remote current control is connected to the welding power source, initial amps, initial
slope, final slope and final amps are controlled by the remote control, not by the welding power source.
Remote 2T
P/R
P/R = Push and release trigger.
.
If torch trigger is held more than 3 seconds, operation reverts to RMT STD (Remote Standard) mode.
Remote 4TE
P/R
P/R = Push and release trigger;
*Push and releasing during final slope will break the arc and go to postflow.
.
For first torch trigger push & release, if trigger is held more than 3 seconds, trigger cycle ends.
.
When a remote switch is connected to the welding power source, use the remote switch to control the weld cycle.
Amperage is controlled by the welding power source.
Application:
Use 4T Momentary trigger method when the functions of a remote current control are desired, but only a remote on/off
control is available.
.
A complete Parts List is available at www.MillerWelds.com
Main Amps
Initial Slope
P/R
Final Slope
Final Amps
R
Maintained Switch
P/R
P/R
*P/R
Postflow
R
Foot Or Finger
Remote Control
P/R
OM-270536 Page 59